Omega FMG600 Series User Manual page 34

Electromagnetic flow meters
Table of Contents

Advertisement

Menu: Output function, depress
The display will read "Pulse width [1] xxx". Move the cursor using push-button
values at various "x" positions using push-buttons
when multiplied by 10, will give the pulse width in ms. Depress
Press any key". Press any key, preferably
Move the cursor using push-button
respectively. Replace xxx by a figure which, when multiplied by 10, will give the gap length in ms. Depress
. The display will read "Value entered Press any key". Press any key, preferably
show the message "Volume per pulse [1] xxxxxxx". Move the cursor using push-button
increase/decrease the "x" values using push-buttons
equal to the desired fluid volume per pulse. This figure is elsewhere referred to as the impulse constant or
impulse number. Depress
preferably
. This will return the display to the menu items "Output 1 function" or Output 2 function". To
return to the basic menu, depress push-button
Pulse number selection for FMG600 SERIES
Dimension
Qmax
Inches (DN)
l/s
½ "
15
1.8
¾ "
20
3.33
1"
25
5
-
32
8.33
1½"
40
12.5
2"
50
20
-
65
33.33
3"
80
50
4"
100
77.77
-
125
119.44
6"
150
180.55
8"
200
319.4
10"
250
500
12"
300
700
1 gallonUS = 3.785412 l
pulse width = 100 ms
minimum gap length = 100 ms
f <= 5Hz
Impulse number selection for FMG600 SERIES for sensors Tri Clover
Dimension
Qmax
Inches mm
l/s
½ " 12.70
0.6940
¾ " 19.05
1.9483
1"
25.40
3.8360
1½" 38.10
9.5115
2"
50.80
17.7205
2½" 63.50
28.4631
Design, Assembly and Service Manual
Induction flow meter FMG600 series
/ Output 1 (2) function, depress
. The display will then show the message "Gap length [1] xxx".
, and increase/decrease the values using push-buttons
. The display will read "Value entered
Imp.number Qmax
l/imp
GPM
28.53058
1
52.78157
1
79.25161
1
132.03318
5
198.12903
5
317.00644
5
528.29124
10
792.51611
10
1232.67956
50
1893.16249
50
2861.77568
50
5062.59292
100
7925.16112
100
11095.22557
500
0.264172037 gall = 1 l
15.85032224 gall/min = 60 l/min
Imp.number Qmax
l/imp
GPM
11.0001
1
30.8812
1
60.8018
1
150.7603
5
280.8756
5
451.1493
10
/ Pulses for |Q|, depress
or
, respectively. Replace xxx by a figure which,
. The display will read "Value entered
or
, respectively. Replace xxxxxxx by a figure
.
coefficient
Imp.number
gallon/imp.
3.785412
3.785412
3.785412
3.785412
3.785412
18.92706
18.92706
18.92706
18.92706
37.85412
37.85412
189.2706
189.2706
189.2706
coefficient
Imp.number
gallon/imp.
3.7854
3.7854
3.7854
3.7854
18.9270
18.9270
Page 32 of 44
.
, and increase/decrease the
. The display will then
Press any key". Press any key,
1
1
1
1
1
5
5
5
5
10
10
50
50
50
1
1
1
1
5
5
or
,
, and

Advertisement