Kyocera KM-3050 Service Manual page 85

Hide thumbs Also See for KM-3050:
Table of Contents

Advertisement

Maintenance
item No.
Setting: adjustment of the paper stop timing
U246
1. Select PUNCH POS ADJ.
2. Change the setting using the +/- or numeric keys.
Description
Adjustment of the paper stop timing
If the distance of the position of a punch hole is smaller than the specified value A, increase the preset
value. If the distance is larger than the value A, decrease the preset value.
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop key.
Setting: adjustment of front/rear side registration home position
1. Select [WIDTH F HP ADJ] or [WIDTH R HP ADJ].
2. Change the setting using the +/- or numeric keys.
Description
Adjustment of front side registration home position
Adjustment of rear side registration home position
3. Press the start key. The value is set.
4. Press the stop key. The screen for selecting a maintenance item No. is displayed.
5. Enter maintenance mode U240 and select [FINISHER MOTOR], then [WIDTH TEST(A3)].
The width guides of the internal tray will move to A3-size position.
6. Pull the internal tray, insert paper between the guides and check that paper is abut the guides.
7. Repeat the above adjustment until paper is properly in position.
Setting: adjustment of front and back stapling home position
1. Select [STAPLE HP ADJ].
2. Change the setting using the +/- or numeric keys.
Description
Adjustment of front and back stapling home position
When staple positions are off toward the front side of the machine (sample 1), increase the preset value.
When staple positions are off toward the rear side of the machine (sample 2), decrease the preset value.
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop key.
A
Figure 1-3-19
Sample 1
Figure 1-3-20
Description
Setting
range
-10 to 10
Preset value A: 5.5 + - 2 mm (inch)
Setting
range
-10 to 10
-10 to 10
Setting
range
-10 to 10
Sample 2
2GN/2GP/2GR
Initial
Change in
setting
value per step
0
0.49 mm
9.5 + - 2 mm (metric)
Initial
Change in
setting
value per step
0
0.314 mm
0
0.314 mm
Initial
Change in
setting
value per step
0
0.32 mm
1-3-55