Installation - Bosch ISN?SM?80 Installation Manual

Seismic detector
Hide thumbs Also See for ISN?SM?80:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4. Mount detector.
Seismic detector ISN−SM−80
Do not use silicon grease between sensor and object!

Installation

Indirect installation with mounting plate GMX−P0
fig. 9 to 12
Application
In the case of uneven or hardened steel plates, weld on
The ISN−SM−80 is a seismic detector with new detec-
mounting plate GMX−P0.
tion and parameterizing features.
1. Remove residual paint from the welding area (fig. 9).
The detection is improved by the patented distur-
2. Weld mounting plate in four fixing points. Ensure cor-
bance filter and new clock filter.
rect positioning (fig. 11).
ü The welding symbol must be visible on the front of
The detector may be used together with ultrasonic de-
tectors.
the mounting plate (fig. 10).
The seismic detector ISN−SM−80 provides reliable pro-
3. Weld along surfaces indicated. Tap off slag and re-
tection for
move weld spatter from the plate surface (fig. 12).
− safes
4. Mount detector.
− strongroom walls
Do not use silicon grease between sensor and
− modular vaults
mounting plate!
− strongroom doors
Installation on concrete using mounting plate
− automatic cash dispensers
GMX−P0 fig. 13
− special light-weight safes (LWS) (synthetic armouring
Never install the detector directly on a bare or plastered
systems)
concrete surface, since bending forces may cause
against attack with explosives and break-in attempts
damage to the seismic sensor. Plaster of less than
with any of the known tools, such as diamond-head
10mm need not be removed.
drills, hydraulic pressure tools, oxygen lances and at-
1. Drill center hole
tack using explosives.
deep using a sintered carbide bit (fig. 13).
Coverage area fig. 1 + 2
2. Insert metal plug into drilled hole flush with the con-
crete surface. Use metal plugs only!
The coverage area is highly dependent on the material
of the object to be monitored. Practical experience has
3. Ensure that the mounting plate is correctly posi-
shown that the operating radius for steel and reinforced
tioned. Press the mounting plate onto surface, knock
concrete is «r» = 16ft. (5m) (fig. 1).
in screw with plug and tighten well. The plate should
The coverage area of the detector on strongroom
no longer be capable of rotation.
walls may also extend to part of the ceiling, floor, or
4. Mount detector.
over corners if an homogeneous connection exists. In
Do not use silicon grease between sensor and
such cases the operating radius is reduced to ¾ of the
mounting plate!
range setting (fig. 2).
Recessed mounting with wall recess plate
Joints between two materials always damp the struc-
GMX−W0 fig. 14 to 16
ture-borne noise transmission. One detector on the
door and one on the body must always be installed.
1. Drill
This also applies to entrance doors of strongrooms.
2. Fasten the wall recess set by inserting threaded bolt
For modular vault applications please refer to the spe-
and tightening wing nut (fig. 14).
cial instructions (page 2) for modular vaults.
3. Push the installation conduit through the polystyrene
block.
Surveillance of the surface fig. 3 + 4
4. After removing mould, unscrew threaded bolt.
To simplify the planning procedure on large surfaces,
Scrape out polystyrene and cut off conduit flush (fig.
the circular coverage area can be considered as a
15).
square:
5. Mount detector.
For 75% surveillance of the surface: diameter within
6. Mount cover plate (fig. 16).
square = 32ft. x 32ft. = 1024sq.ft. (10m x 10m =
2)
100m
. See fig. 3.
Cable feed in wall box and floor box fig. 17
For standard surveillance of the surface: square in
Insert cable with reserve loop into the box. Ensure ap-
2
circle = 23ft. x 23ft. = 529sq.ft. (7m x 7m = 49m
). See
propriate cable length when drawing the cable in.
fig. 4.
It is of course also possible to choose intermediate val-
Installation in floor box GMX−B0 fig. 18 to 20
ues. Several detectors may be installed on the same ob-
To install the floor box GMX−B0, a recess with a base
ject.
area of at least 12" x 12" (300 x 300mm) and a depth of
3¼" (80mm) is required (fig. 18). Use a polystyrene
block to keep this recess open when pouring in the wet
Installation
concrete.
Opening the detector fig. 5
Two threaded bolts M6x4" (M6x100mm) screwed into
Unscrew the captive screws and lift off the metal cover
metal plugs provide the acoustic connection between
carefully.
the detector and the concrete floor.
− The seismic sensor is now exposed.
1. Level floor box using the nuts on the two threaded
bolts. Fix position finally by tightening the lock nuts
Fastening the detector fig. 5
(fig. 19).
Use only the two pre-assembled M4 cross-head screws
2. Feed installation conduits through sealing sleeves.
provided in order to fix the detector.
Fill recess with wet cement.
3. Pull cable through and thoroughly seal the entry
Direct mounting on steel fig. 6 to 8
openings for protection against moisture (fig. 20).
The detector can be installed directly on steel plates
4. Mount the detector.
with a smooth surface. Ensure that any residual paint
5. Fit cover plate. Cut out wood or carpet floor covering
between the steel surface and the seismic sensor is
and stick to cover plate.
completely removed and the mounting surface is level
1
to within
/
" (0.1mm). If this is not possible, use
128
mounting plate GMX−P0.
Installation accessories
1. Remove residual paint from sensor installation site
(fig. 6).
GMX−D7 Anti-drilling foil fig. 5
2. Stick on drilling template and centerpunch drill holes
A special anti-drilling foil is available for fitting into the
(fig. 7).
detector cover as an additional protection against tam-
1
3. Drill only the two marked holes of
/
" (3.2mm) dia.
pering, if required. For installation refer to the separate
8
1
mounting sheet delivered with the GMX−D7.
and tap M4 thread at least
/
" (6mm) deep (fig. 8).
4
Deburr threaded holes.
008739_b_−−_−− page 3
Papiergrösse = 360 x 270mm
Programming
After the detector housing has been opened, use the
switches to select the respective settings.
SW1, SW2
Application settings, SW1 and SW2
Select the sensitivity setting to suit the application, the
material and the object with the associated interference.
Important: During commissioning, be sure to check for
function-related noise (see "Commissioning" ).
Settings on the detector
Concrete 13ft. (4.0m)
Steel 6ft. 8" (2.0m)
LWS 6ft. 8" (2.0m)
3
/
" (10mm) dia. at least 2" (50mm)
8
User Mode, with SMS−W7 SensTool
Remote controlled sensitivity reduction fig. 22
An additional feature of this detector is a sensitivity re-
duction input at terminal 7 "Remote" which can be re-
motely activated if required.
Using a LOW signal (0V), the detector is reduced to
about 1/8 of the sensitivity setting for as long as there is
heavy functional noise by means of a touch-sensitive
switch on the opening device during operation of day-
night deposit.
ü Open control input is HIGH (internal pull-up resistor).
3
/
" (9mm) dia. hole in wooden concrete mould.
8
Test input fig. 22
The test input terminal 4 is used for the functional testing
of the seismic detector together with the GMX−S1.
With TEST ON the functional test is run once and a pos-
itive test result is output to the alarm relay.
ü Open control input is HIGH (internal pull-up resistor).
LED
During commissioning or when changing operating
mode the red LED flashes until the detector is ready for
operation.
Lights on alarm condition for approx. 2.5s.
Commissioning
If the GMX−S1 test transmitter is to be used, it must be
connected before power is switched on.
Procedure:
1. Switch on voltage − wait 1 minute − the detector is
ready for operation.
2. Functional check: Simulate an attack signal in the su-
pervised area, for example scratch lightly with a
screwdriver or test signal GMX−S1 − the detector
should trigger an alarm.
3. Interference checks: Connect an universal measur-
ing instrument (impedance ≥20kΩ) between terminal
1 (0V) and "TEST POINT" for integrator signal:
− quiescent level
− integration start
− alarm threshold (without load)
4. Carefully close the cover, tightening the housing
screw.
SensTool SMS−W7
The SensTool software allows operating parameters to
be set individually. In addition, current information such
as integrator signals can be viewed and stored.
The following additional settings are possible, depend-
ON
ing on the application, material and object, with corre-
OFF
sponding interferences:
1 2
Detector sensitivity
y
ON
OFF
1 2
Shock sensitivity
y
ON
OFF
1 2
Recommended sensitivity settings
ON
The following approximate values can be used as refer-
OFF
ence values for the setting of the seismic detector:
1 2
ON
Application
OFF
Autom. cash dispenser, Day/night
1 2
deposit, Safe door
with heavy functional related noises
Armoured safe, Strongroom door
with functional related noises
Strongroom, Modular vault
with light interferences
Strongroom, Modular vault
with low interferences
Strongroom, Modular vault
with minimum interferences
Synthetic armoured system:
autom. cash dispenser
with functional related noises
Synthetic armoured system:
modular vault
with minimum interferences
Maintenance
Test detectors regularly (at least once a year) for opera-
tion and firm mounting.
Approvals
CE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Any national approval requirements relating to the ap-
plication of the product must be complied with.
0V
. . . . . . . . . . . . . . . . . . . . .
1.0V
. . . . . . . . . . . . . . . . . . . .
3.0V
. . . .
Technical data
Detector
Supply voltage (nom. 12V
)
DC
. . . . . . . . . . . . . . . .
Current consumption (at 12
, quiescent)
DC
− alarm condition
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm output, terminals 14+15:
Semiconductor relay
. . . . .
opens on alarm and/or low voltage
4ft. 9" (1.5m)
− contact load
. . . . . . . . . . . . . . . . . . .
30V
Steel
Steel
− series resistance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6ft. 8" (2.0m)
Alarm holding time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8ft. 2" (2.5m)
Sabotage surveillance:
Tamper, terminals 10+11:
Concrete
13ft. (4.0m)
− microswitches for cover + body
. . . . . . . . .
16ft. (5.0m)
− contact load
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . .
4ft. 9" (1.5m)
Anti-drilling foil in cover
LWS
LWS
. . . . . . . . . . . . . . . . . . . .
6ft. 8" (2.0m)
Sensitivity reduction input, terminal 7:
LOW ≤1.5V / HIGH ≥3.5V
low
− for reduction
. . . . . . . . . . . . . . . . . . .
− reduction to
1/8 of the actual setting
. . . . . . . . . . . . . . . . . . . . . .
mid
Sensitivity, adjustable in
. . . . . . . . . . . . . . . . . . . . .
high
SW programmable with SensTool
Functional test input, terminal 4:
LOW ≤1.5V / HIGH ≥3.5V
− for test
. . . . . . . . . . . . . . . . . . . . . . . .
− with GMX−S1, test duration
. . . . . . . . . . . . . . . . . . . . . . . . . .
Measuring output, TEST POINT analogue integration signal
.
− quiescent level
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensitivity
Shock
− integration start
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
− alarm treshold (without load)
Steel
. . . . . . . . . . . . . . . . . . . . . . . .
mid
4ft. 9" (1.5m)
Operating radius on concrete
. . . . . . . . . . . . . .
Steel
Coverage area on concrete
. . . . . . . . . . . . . . . .
mid
6ft. 8" (2.0m)
Ambient conditions:
Concrete
− operating temperature −40°F to +158°F (−40°C to +70°C)
high
8ft. 2" (2.5m)
− storage temperature
−58°F to +158°F (−50°C to +70°C)
. .
− humidity, DIN class F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Concrete
high
− housing protection category (EN60529, EN50102)
13ft. (4.0m)
− VdS environmental class
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Concrete
− insensitive to RD interferences
high
16ft. (5.0m)
0.01...2GHz (IEC 801-3)
. . . . . . . . . . . . . . . . . . . . . . . . . .
LWS
high
Accessories
4ft. 9" (1.5m)
GMX−W0 Wall recess set with cover
LWS
− housing protection category IEC
. . . . . . . . . . . . . . . . . . . .
high
− max. carrying capacity of cover
6ft. 8" (2.0m)
. . . . . . . . . . . . . . . . . . . . .
GMX−B0 Floor box
− housing protection category IEC
. . . . . . . . . . . . . . . . . . . .
− max. carrying capacity of cover plate
GMXW−G0 Watertight housing
− housing protection category IEC
. . . . . . . . . . . . . . . . . . . .
− max. carrying capacity of cover
. . . . . . . . . . . . . . . . . .
Details for ordering
conforms
Elements supplied with detector
applied for
1 Seismic detector
1 Mounting instructions
1 Mounting template
3 Cable straps
Seismic detector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting plate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall recess set w/cover
. . . . . . . . . . . . . . . . . . . . .
Floor box
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Watertight housing
. . . . . . . . . . . . . . . . . . . . . . . .
Swivel plate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test transmitter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SensTool, interface and software
. . . . . . . . . . . .
Anti-drilling foil (10 pcs)
. . . . . . . . . . . . . . . . . .
Fixing plate
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spacer, 2mm
. . . . . . . . . . . . . . . . . . . . . . . . .
Spacer, 4mm
. . . . . . . . . . . . . . . . . . . . . . . . .
Swivel plate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.0...16.0V
DC
typ. 3mA
. . . . . . . . .
5mA
/100mA, ohmic load
DC
≤45Ω
2.5s
opens on tamper
30V
/100mA
DC
<7V...8V ⇒ alarm
tamper ⇒ alarm
3 fixed levels +
≤3s
0V
1,0V
3,0V
r = 16ft. (5.0m)
2
256sq.ft. (80m
)
<95%
IP435
. .
III
30V/m
IP51
25kg
IP51
. . . . . . . . . . . . .
1000kg
IP65
1000kg
ISN−SM−80
ISN−GMX−P0
ISN−GMX−W0
ISN−GMX−B0
ISN−GMXW−G0
ISN−GMX−P3S
ISN−GMX−S1
ISN−SMS−W7
ISN−GMX−D7
ISN−GMA−S6
ISN−GMX−P3S2
ISN−GMX−P3S4
ISN−GMX−PZ