Page 6
Note: The accessories are held in the tool by
FIG. 6
a collet system. The accessory may be
installed before or after the rotary tool is
installed in the tool holder.
1. With the tool unplugged and in the off
ROTARY TOOL
position, remove the nose cap from your
rotary tool to expose the threaded nose.
Depress and hold the shaft lock button while
rotating the collet nut and shaft. Continue to
rotate the collet nut and shaft until the lock
engages and holds the shaft.
2. Use the wrench from your Dremel Rotary
Tool and turn the collet nut counterclockwise
to loosen it.
TOOL HOLDER
3. Release the shaft lock button.
ADAPTER
4. Insert the accessory into the collet as deep
as possible to ensure proper gripping of the
UNION NUT
accessory and to minimize run out. Do not
insert the bit so far that the flutes touch the
collet or collet nut to avoid chipping or
cracking the bit.
5. Re-engage the shaft lock button and
tighten the collet nut; first by hand, then using
the wrench until the bit is held securely.
6. Place the threaded nose through the open
ring of the adapter and place the union nut
provided on the threaded nosepiece. Hand
tighten the union nut until the nut is fully
threaded on to the tool. Using the wrench
provided, tighten the union nut until it is tight
and the rotary tool is securely in place.
-6-