1) The command group
05h (base 16) = SE500 control command
2) The operated refer to section 4.
3.2 Return data format
th
th
4
5
Command
parameter
Status
#0
1) The command status
05h=SE500 control command status
2) The parameter refers to section 6.
4.
The operated of SE500 control command
5th
Operated
#0
Mode
Code
4.1. OP#0 = Control mode code
00H = Ask status
01H = Normal key control
02H = T-BAR control
OP#1 = control key code.( refer to section 5) when OP#0=01H
= 00h= disable remote control T-bar when OP#0=02H
= 01h= enable remote control T-bar when OP#0=02H
4.2. OP#2 and OP#3 = T-BAR control value when OP#0=02H
The T-bar control value is 10 bits
The bit4 to bit 0 of OP#1 = the low 5 bits of the T-bar control value.
The bit4 to bit 0 of OP#2 = the high5 bits of the T-bar control value.
5. The SE500 control key code
(Base 16)
01h = key_main_A
02h = key_main_B
03h = key_main_C
04h = key_main_D
05h = key_main_BK
06h = key_sub_A
07h = key_sub_B
08h = key_sub_C
09h = key_sub_D
0ah = key_sub_BK
0bh = key_QUAD
0ch = key_POP
0dh = key_freeze
0eh = key_preview
0fh = key_take
10h = key_fade
11h = key_center_block
12h= key_right_top_block
13h= key_right_bottom_block
14h= key_left_top_block
th
6th
7
parameter
parameter
#1
#2
6th
7th
Operated
Operated
#1
#2
Key
T-bar
code
low
(wipe)
(wipe)
(wipe)
(wipe)
8th
9th
parameter
parameter
#3
#4
8th
Operated
#3
T-bar
high
36
10th
11th
...
parameter
parameter
...
#5
#6