GE Homespring Owner's Manual

Water purifier system
Hide thumbs Also See for Homespring:

Advertisement

Homespring
by GE
TM
Water Purifier System
Owners Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for GE Homespring

  • Page 1 Homespring by GE Water Purifier System Owners Manual...
  • Page 2: Table Of Contents

    Table of Contents: A. INTRODUCTION ............3 B. SAFETY WARNINGS ..........4-5 C. CERTIFICATION ............5 D. OPERATIONS ............6-8 E. MAINTENANCE SCHEDULE ......9-11 F. WINTERIZATION ..........12-15 G. TROUBLESHOOTING ........15-16 H. REPLACEMENT PART LIST AND PROCEDURES ........17-21 I. SPECIFICATIONS ............21 J.
  • Page 3: Introduction

    By purchasing the Homespring Water Purifier System, you features of the Homespring Water Purifier System. It is not have taken the first step in providing safer, great tasting water intended to be a definitive dissertation on the principles set for your entire home.
  • Page 4: Safety Warnings

    After the installation of the System if described in this manual. any noticeable pressure drop occurs, call your local Homespring Authorized Service Person. The System must be winterized prior to temperatures falling below 32°F(0°C). Failure to do so may cause the...
  • Page 5: Certification

    Failure to do so may cause System to dry Program (NELAP) Accredited #05234CA and become damaged, leading to personal injury, and/ The Homespring UF200 Series Water Purifiers have or physical damage and will void all warranties. been tested by BioVir Laboratories Inc. and found A bypass is not required for proper operation of the to meet all the requirements of the USEPA’s Guide...
  • Page 6: Operations

    Normal operation will resume once the flushing and draining sequences are finished. Once the Homespring Authorized Technician has completed Follow these steps to set the Controller: the System installation, the System must be flushed before use.
  • Page 7 Setting the Program Setting the Clock Choosing a program: NOTE: If surface water is the source and the Surface Water Option Kit is installed, select either Program 3 or Program 4 in this application. Water Clarity Advanced Plus Controller Low Turbidity Program 1 Less than 0.5 NTU FIGURE 2...
  • Page 8: Controller Functions

    “A oF” (alarm off) will appear on the screen. To turn the alarm on again, repeat the above step. “A on” (alarm on) will appear on the screen. The yellow service indicator light and the alarm can only be reset by a Homespring Authorized Technician during the Annual Maintenance.
  • Page 9: Maintenance Schedule

    Backpulse possible death. Tank Air Check and adjust Pressure Controller A Homespring Authorized Technician must perform all service Batteries Replace and maintenance. As part of the annual maintenance, the (2 AA) Homespring Authorized Technician will perform an Integrity Controller...
  • Page 10 Close the Inlet and Outlet Valves. Using the Controller, For Ground Water Systems, refer to Ground Water initiate a Manual Flush sequence to bring System pressure Application Cleaning Procedures section before beginning close to zero. Refer to the instructions in the Controller this step.
  • Page 11 Ground Water Application Cleaning Procedures Annual Maintenance Check Summary For ground water installations, clean the membrane following The Homespring Authorized Technician performs the following the steps above with the exception of replacing Step 4 with maintenance tasks during the annual maintenance visit.
  • Page 12: Winterization

    F. WINTERIZATION PROCEDURE Remove the drain hose and Nylon Elbow from the Drain Tools/Supplies Required Solenoid Valve and install a ½” MNPT or ¾” MNPT PVC plug (depending on the size of the port) into the Drain Solenoid For all Systems you will need: Valve.
  • Page 13 Spring Start-Up Following Winterization Remove the System Cap and remove the Prefilter. If the System is equipped with the Carbon Prefilter, discard the Carbon Prefilter. If the System is equipped with the Stainless WARNING: Steel Prefilter, clean and set aside the Stainless Steel Prefilter Do NOT allow the temporarily.
  • Page 14 Open a nearby cold water high demand tap, then open Be sure the water level in the System is 2” above the the Outlet Valve. This will prevent antifreeze from spreading bottom of the Prefilter cavity. Add more water by slowly throughout the piping system.
  • Page 15: Troubleshooting

    G. TROUBLESHOOTING If there are any problems with the Homespring Water Purifier System, contact your dealer or Homespring Customer Service immediately. Area...
  • Page 16 5 seconds. A buzz sound should be does not work heard from both the Inlet and Drain Solenoid Valves. Contact your Homespring Dealer if necessary. Check the settings. Refer to Setting the Controller under D. OPERATIONS.
  • Page 17: Replacement Part List And Procedures

    H. REPLACEMENT PART LIST AND Check that the Thimble Filter is in place, seated in the spigot. DO NOT attempt to remove the Thimble Filter. If PROCEDURES the Thimble Filter is loose, gently push it into place. Replacement Procedures Remove the new Internal Prefilter from the packaging. Insert the new Internal Prefilter into the Prefilter cavity A.
  • Page 18 UFC 211 and UF 211 Series 17 18 FIGURE 20...
  • Page 19 UFC 211 and UF 211 Series Item Part Description UFC 211/ UF 211 Number System 3024924 Carbon Prefilter, 12” UFC models only 3024923 Stainless Steel Prefilter, 12” UF models 3024983 O-ring, 8” 2-443, EPDM, 70A, NSF61 3025097 Owner’s Manual 3035399 Advanced Plus Controller - DC 3025180 Long Cap...
  • Page 20 Surface Water Option Kit Item Part Description Surface Number Water Option Surface Water Option Kit/External Prefilter Kit Parts 3024925 External Prefilter Replacement Cartridge 3024984 O-ring for External Prefilter 3025175 Reducer Bushing, 1" x 3/4" 3035503 Inlet Solenoid Valve, 3/4", Normally (CH21092) Open - DC 3030404...
  • Page 21: Specifications

    I. SPECIFICATIONS Controller Specifications Advanced Plus Controller Parameter UFC 211/ UF 211 • Fuse - 3.0 Amp Maximum continuous flow rate 4.5 gpm (17 Lpm) • Voltage In - 24 VDC Pressure drop at maximum continuous 5 psi (34.5 kPa)/ flow rate when new, at 25°C 4 psi (27.6 kPa) •...
  • Page 22: Faq

    J. FREQUENTLY ASKED QUESTIONS (FAQ) a number of flushes and drains to clean the membrane. For Systems equipped with an Advanced Plus Controller, System What does the System do? cleaning may be performed multiple times per day, up to 24 This System has been times.
  • Page 23 I. SPECIFICATIONS. To maintain warranty, the System must be serviced by a Homespring Authorized Technician at least once per year. If the System unit removes chlorine out of the During this service, the system is cleaned and tested using the...
  • Page 24: Warranty

    The carbon filter may help in the reduction of taste and odour caused by sulphur. K. HOMESPRING WATER PURIFIER SYSTEM LIMITED WARRANTY Please refer to your local dealer for all Warranty, Technical and Service questions.

This manual is also suitable for:

Homespring ufc 211Homespring uf 211