Activate The Override Input Function; Activate The Alert/Evac Override Function; Operating The Dsp Matrix Mixer/System With The Gui - Bosch PLENA matrix Operation Manual

Public address system
Table of Contents

Advertisement

40
en | Operation
8.5.1

Activate the override input function

The active override function is used when you want to temporarily override all existing
configurations on all outputs, with a signal supplied by the override audio input.
1/2
3
Power
Amp Link Out 1-4
Amp Link Out 5-8
1.
2.
8.5.2

Activate the Alert/EVAC override function

These override functions are used when you want to override all existing configurations in all
zones, with an internally generated alarm signal.
1.
2.
8.5.3

Operating the DSP Matrix Mixer/system with the GUI

Operating and configuration of the DSP features can only be used via the DSP matrix mixer PC
GUI. Refer to DSP matrix mixer PC GUI, page 26. Operation instructions are available within the
help of the PC GUI.
2013-06 | V1.0 |
4
Out 1
Out 2
Out 3
Out 4
Mic/Line 1
Out 5
Out 6
Out 7
Out 8
Trigger the active audio override contact closure on the units rear panel (7) via the
phoenix connection labeled "Active":
The override input signal (8) now has a higher priority than all the other input
sources, and is active immediately into all channels.
By opening the contact again, the override input signal stops. The unit will restore
and return to its prior configuration immediately.
Activate the "Force into override" via the PC GUI:
The override input signal overrules all active audio signals.
Activate the audio override via contact closures the units' rear panel (7) using an external
device:
The override input signal overrules all active audio signals.
By opening the contact again, the override tone stops. The unit will restore and
return to its prior configuration immediately.
Activate the "Force into Alert Tone" or "Force into EVAC Tone" via the PC GUI:
The override input signal overrules all active audio signals.
5
L
R
Line 5
Mic/Line 2
Mic/Line 3
Mic/Line 4
Operation manual
6
7
9
Link/Act
100Mbps
Line 6
Line 7
Network
Override
8
Bosch Security Systems B.V.
PLENA matrix
10
Control Panels
Call Stations
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents