Defects Associated with Specific Printer Components

Some print-quality problems can be associated with specific assemblies, the most
common problems and the associated assemblies are listed below. Also, refer to
the printer's Troubleshooting Print-Quality Problems pages or a specific print-
quality troubleshooting procedure for more information.
Imaging Unit
Transfer Unit
Fuser
LED Head
Test Prints
A variety of test prints are available to aid in determining the quality of output
from the printer and to assist in troubleshooting. The next section shows how to
generate and analyze test prints
Streaks in Process Direction (in the direction of feed,
parallel with paper travel)
Banding in Scan Direction (across the page,
perpendicular to paper travel)
Uneven Density
Voids
Repeating Defects
Mis-registration
Toner on the back side of the printed page
(simplex mode)
Light Prints
Repeating Defects
Mis-registration - only when there is obvious
damage to the belt.
Hot or Cold Offsetting
Repeating Defects
Dark Streaks in Process Direction
Streaks in the Process Direction
Uneven Density in the Scan Direction