PRE-OPERATING INSTRUCTIONS
1. Carefully remove your heater from the box.
(please save the carton for off-season storage).
2. Make sure the unit is in the OFF position before plugging
the heater into the outlet.
3. Place heater on firm level surface.
4. Avoid overloading your circuit by not using other high wattage
appliances in the same outlet. At 1500 Watts, this unit draws
12.5 Amps.
ACCUTEMP™ DIGITAL THERMOSTAT
Your heater is equipped with an AccuTemp™ Digital Thermostat
that allows you to set your heater to your precise comfort level.
Setting the AccuTemp™ thermostat:
1. Make sure the Manual/AccuTemp™ switch is set to AccuTemp™.
The LCD display will read 25°.
2. Turn the mode control to LO, MED or HI.
3. Push the temperature set button until the display reads your desired
temperature. To increase the temperature push the top button, for
lower temperatures push the lower button. When finished setting the
temperature, release the button and the display will flash to indicate
the thermostat will be set to that temperature.
4. The display will return to existing room temperature and gradually
increase until the room has reached your pre-set temperature.
5. If the unit will not start in the AccuTemp™ mode, please make sure
the "set temperature" is higher than the current room temperature.
NOTE: It is normal for the heater to cycle ON and OFF as it maintains
the preset temperature. To prevent the unit from cycling, you need
to raise the thermostat setting. When the preset temperature is made,
the fan will run for 30 seconds without heat. This cool down process
ensures an accurate and consistent temperature reading. If you unplug
the heater, you will have to reset the AccuTemp™ thermostat again by
following the above instructions.
Manual Operation:
1. If you want the heater to run continuously, turn the
Manual/AccuTemp
switch to Manual and adjust the
mode control to LO, MED or HI.
ILLUSTRATIONS
A
C
B
H
Figure 1
E
G
A. POWER LIGHT
D
B. MODE CONTROL
C. LCD DISPLAY
SCREEN
D. OSCILLATION
SWITCH
E. CARRY GRIP
F. OSCILLATION BASE
F
G. TEMPERATURE SET
BUTTON
H. MANUAL/ACCUTEMP
SWITCH
CLEANING/MAINTENANCE
During Season Care:
Always unplug the heater, before moving or cleaning.
1. Carefully wipe the unit with a soft, damp cloth. Please
be very cautious near the motor and heating elements.
2. After cleaning, be sure to completely dry the unit with
a cloth or towel.
After Season Care:
1. Store heater in a cool, dry location.
2. Holmes recommends that you store the unit in its original carton.

TROUBLESHOOTING

If your heater fails to operate:
• Make sure the electrical outlet or circuit breaker is working.
• Check for obstructions. If you find an obstruction turn the heater OFF,
and unplug the unit. Carefully remove the obstruction and follow the
reset instructions.
• The thermostat might be set too low. Adjust the thermostat until the
heater restarts.
• Make sure selector is in LO, MED, or HI setting.
If your heater fails to oscillate:
• Make sure the oscillation button is pressed.
Incorrect Room Temperature Display:
1. Allow a few minutes for the heater to adjust to the room
temperature.
2. Switch unit to Accutemp. Use touch pad to set desired temperature.
Please DO NOT attempt to open or repair the heater.
Please see the Warranty for Service Instructions.
Figure 2
C
B
HEAT CONTROLS
OFF
FAN
LOW 500W
MED 1000W
HI 1500W
A
G
D
H

Advertisement

loading

This manual is also suitable for:

Hfh595Accutemp hfh595-cn