Download Print this page

American Standard Pekoe Extender Single Control Kitchen Pop-Out Spray 4335.020.XXX Installation Instructions page 3

American standard pekoe extender single control kitchen pop-out spray installation instructions

Advertisement

4
SERVICE
Clogged CARTRIDGE outlets or inlets may cause reduced
flow. To clean, first turn off water supply then:
Loosen and remove LEVER HANDLE (1). Loosen
HANDLE SCREW (2) with 2.5mm Hex Wrench and
then pull HANDLE BASE (3) off.
Unscrew ESCUTCHEON CAP (4). Unscrew the
CARTRIDGE NUT (5) and remove METAL WASHER (8).
Remove CARTRIDGE (6). Clean inlets of
CARTRIDGE (6) and MANIFOLD (7).
Reassemble CARTRIDGE (6). Replace CARTRIDGE
NUT (5), CAP (4), METAL WASHER (8) and
HANDLE assembly, check flow.
5
SERVICE
If SPOUT (1) leaks at swivel point the O-RINGS (2) need
to be replaced. To remove SPOUT (1):
Turn faucet to off position. Loosen the SPOUT SET SCREW (3)
with a 3mm Hex wrench.
Rotate the SPOUT (1) side to side while pulling upward to
remove SPOUT (1) from faucet body.
Replace the defective parts and grease O-RINGS (2). Push
SPOUT (1) back into position. Tighten SET SCREW (3).
Check that SPOUT (1) rotates freely and does not leak
at the swivel point.
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
8
METAL
WASHER
CLEAN
5
7
6
3
1
REMOVE
INSTALL
2
3
3mm HEX
WRENCH
1
4
2
M 9 6 8 5 8 2