Warnings And Cautions; Diagnostic Test Indicators; Self-Diagnostic Function - Sony Trinitron KV-32XBR400 Service Manual

Trinitron color tv
Hide thumbs Also See for Trinitron KV-32XBR400:
Table of Contents

Advertisement

KV-32XBR400/36XBR400/36XBR400H/38DRC1/38DRC1C
CAUTION
SHORT CIRCUIT THE ANODE OF THE PICTURE TUBE
AND THE ANODE CAP TO THE METAL CHASSIS, CRT
SHIELD, OR CARBON PAINTED ON THE CRT, AFTER
REMOVING THE ANODE.
WARNING!!
AN ISOLATION TRANSFORMER SHOULD BE USED
DURING ANY SERVICE TO AVOID POSSIBLE SHOCK
HAZARD, BECAUSE OF LIVE CHASSIS. THE CHASSIS
OF THIS RECEIVER IS DIRECTLY CONNECTED TO THE
AC POWER LINE.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK
ON THE SCHEMATIC DIAGRAMS, EXPLODED VIEWS,
AND IN THE PARTS LIST ARE CRITICAL FOR SAFE
OPERATION. REPLACE THESE COMPONENTS WITH
SONY PARTS WHOSE PART NUMBERS APPEAR AS
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY. CIRCUIT ADJUSTMENTS THAT
ARE CRITICAL FOR SAFE OPERATION ARE IDENTIFIED
IN THIS MANUAL. FOLLOW THESE PROCEDURES
WHENEVER CRITICAL COMPONENTS ARE REPLACED
OR IMPROPER OPERATION IS SUSPECTED.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/STEREO LED will automatically begin to
flash. The number of times the LED flashes translates to a probable source of the problem. A definition of the STANDBY/STEREO LED
flash indicators is listed in the instruction manual for the user's knowledge and reference. If an error symptom cannot be reproduced, the
Remote Commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these
problems occur.

Diagnostic Test Indicators

When an error occurs, the STANDBY/STEREO LED will flash a set number of times to indicate the possible cause of the problem. If
there is more than one error, the LED will identify the first of the problem areas. Due to a hardware upgrade, there is no LED flashing in
sets using Ver.1.0 system micros. This has been addressed in Ver.2.0 system micros.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a "0".
Diagnostic
STANDBY/STEREO
Item/Description
Power does not turn on
+B overcurrent (OCP)
(see Note 1)
Low B overvoltage (OVP)
Vertical deflection stopped
White balance failure
(not balanced)

WARNINGS AND CAUTIONS

SELF-DIAGNOSTIC FUNCTION

No. of times
Self-diagnostic
Display/
LED flashes
Diagnostic result
Does not light
2 times
2:0 or 2:1
3 times
3:0 or 3:1
4 times
4:0 or 4:1
5 times
5:0 or 5:1
APRES AVOIR DECONNECTE LE CAP DE L'ANODE, COURT-CIRCUITER
L'ANODE DU TUBE CATHODIQUE ET CELUI DE L'ANODE DU CAP AU
CHASSIS METALLIQUE DE L'APPAREIL, OU AU COUCHE DE CARBONE
PEINTE SUR LE TUBE CATHODIQUE OU AU BLINDAGE DU TUBE
CATHODIQUE.
AFIN D'EVITER TOUT RESQUE D'ELECTROCUTION PROVENANT D'UN
CHÁSSIS SOUS TENSION, UN TRANSFORMATEUR D'ISOLEMENT DOIT ETRE
UTILISÉ LORS DE TOUT DÉPANNAGE. LE CHÁSSIS DE CE RÉCEPTEUR EST
DIRECTEMENT RACCORDÉ À L'ALIMENTATION SECTEUR.
ATTENTION AUX COMPOSANTS RELATIFS A LA SECURITE!!
LES COMPOSANTS IDENTIFIES PAR UNE TRAME ET PAR UNE MARQUE
SUR LES SCHEMAS DE PRINCIPE, LES VUES EXPLOSEES ET LES
LISTES DE PIECES SONT D'UNEIMPORTANCE CRITIQUE POUR LA
SECURITE DU FONCTIONNEMENT. NE LES REMPLACER QUE PAR DES
COMPOSANTS SONY DONT LE NUMERO DE PIECE EST INDIQUE DANS
LE PRESENT MANUEL OU DANS DES SUPPLEMENTS PUBLIES PAR SONY.
LES REGLAGES DE CIRCUIT DONT L'IMPORTANCE EST CRITIQUE POUR
LA SECURITE DU FONCTIONNEMENT SONT IDENTIFIES DANS LE
PRESENT MANUEL. SUIVRE CES PROCEDURES LORS DE CHAQUE
REMPLACEMENT DE COMPOSANTS CRITIQUES, OU LORSQU'UN
MAUVAIS FONTIONNEMENT SUSPECTE.
Probable Cause Location
• Power cord is not plugged in.
• Fuse is burned out. (F5501)
• H.OUT (Q5030) is shorted. (D board)
• +B PWM (Q5003) is shorted. (D board)
• IC9001,IC9002, IC9003 is shorted. (C board)
• IC6505 is faulty. (D Board)
• +/-15V is not supplied. (D board)
• IC 5004 is faulty. (D board)
• Video OUT (IC9001-IC9003) is faulty. (C
board)
• CRT Drive (IC201) is faulty. (A Board)
• G2 is improperly adjusted. (see Note 2)
— 4 —
ATTENTION!!
ATTENTION!!
Detected Symptoms
• Power does not come on.
• No power is supplied to the TV.
• AC power supply is faulty.
• Power does not come on.
• Load on power line is shorted.
• Has entered standby mode.
• Has entered standby state after
horizontal raster.
• Vertical deflection pulse is stopped.
• Power line is shorted or power
supply is stopped.
• No raster is generated.
• CRT cathode current detection
reference pulse output is small

Hide quick links: