CD SECTION
1. Enter the CD Test mode
(see page 30)
MD EF TG FB
88 07 00 3A0
The above is the default display.
Pressing the ^ key will rotate the CD and pressing the ^
once more will output sounds.
Pressing the ^ key will execute automatic adjustment and
values will change; however, this value is quite normal.
2. RF LEVEL and jitter check
Test mode PLAY status
Connection Point:
Main board
TP(RFO)
TP(VC)
Check to see that the jitter is less than 9.0 nsec.
and RF level is between 1.1 – 1.5Vp-p.
VOLT/DIV : 200mV (using 10:1 probe)
TIME/DIV : 500ns
Oscilloscope
RF level:
1.1 - 1.5Vp-p
– 36 –
3. Traverse signal check
Connection Point:
Main board
CN701 $∞ pin (TEO)
TP(VC)
Press the FF or FR from 2.
Check to see that the traverse signal level is between 400
600mVp-p.
0V
4. After completed with adjustment, press the RESET button to
release the test mode.
Adjustment Location :
[MAIN BOARD] (SIDE A)
IC701 $∞ pin
(TEO)
Oscilloscope
Note:
Extend the sweep time
for easier view.
A
400 – 600mVp-p
0V
B
A = B
TP
TP
(RFO)
(VC)
A
B