2. Remove 2 screws holding temp sensor and replace with
new one.
3. Solder the lead wires securely to the sensor terminals.
18.7. Disassembly of door assembly
1. Remove each 2 bolts holding upper and lower hinges.
2. Open the door and while pulling the door outward, work
upper and lower hinges out through the holes of the front
surface of oven.
3. Remove door C (check cover) from door E by carefully
pulling outward starting from the upper right hand corner.
4. Remove 2 screws holding door handle and separate door A
from door E by carefully freeing catch hooks.
5. Remove door key, door key lever, door key spring and
handle pins from door E.
6. Assemble the door by taking the above steps in a reverse
order.
Replacement
1. When mounting the door to the oven be sure to adjust the
door parallel to the bottom line of the oven face plate by
moving the upper hinge and lower hinge in the direction
necessary for proper alignment.
2. Adjust so that the door has no play between the inner door
surface and oven front surface. If the door assembly is not
mounted properly, microwave may leak from the clearance
between the door and the oven.
NOTE: