MSI 5520 Master Series User Manual

Ms-91c2 (v1.x) server board

Advertisement

Quick Links

5520 Master Series
MS-91C2 (V1.X) Server Board
G52-91C21X1
i

Advertisement

Table of Contents
loading

Summary of Contents for MSI 5520 Master Series

  • Page 1 5520 Master Series MS-91C2 (V1.X) Server Board G52-91C21X1...
  • Page 2: Trademarks

    Alternatively, please try the following help resources for further guidance. Vis i t the MSI webs ite at http ://glob al.msi. com.tw /index. php? for FAQ, technical guide, BIOS updates, driver updates, and func=service other information.
  • Page 3: Safety Instructions

    Safety Instructions Always read the safety instructions carefully. Keep this User’s Manual for future reference. Keep this equipment away from humidity. Lay this equipment on a reliable flat surface before setting it up. The openings on the enclosure are for air convection hence protects the equip- ment from overheating.
  • Page 4: Fcc-B Radio Frequency Interference Statement

    FCC-B Radio Frequency Interference Statement T h is eq uip men t h as been tested and found to c omply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 5: Weee (Waste Electrical And Electronic Equipment) Statement

    WEEE (Waste Electrical and Electronic Equipment) Statement...
  • Page 8: Table Of Contents

    CONTENTS Copyright Notice ......................ii Trademarks ........................ii Revision History ......................ii Technical Support ......................ii Safety Instructions ......................iii FCC-B Radio Frequency Interference Statement ............iv W EEE (Waste Electrical and Electronic Equipment) Statement ........v Chapter 1 Getting Started ..................1-1 Mainboard Specifications ...................
  • Page 9: Chapter 1 Getting Started

    Getting Started Chapter 1 Getting Started Thank you for choosing the 5520 Master Series (MS- 91C2 V1.X), an excellent server board from MSI. Based on the innovative Intel 5520 & ICH10R chipsets ® for optimal system efficiency, the 5520 Master Series ®...
  • Page 10: Mainboard Specifications

    M S-91C2 Server Board Mainboard Specifications Proce ssor - 45nm Intel Gainstown/Nehalem processors in LGA1366 package Supported QPI - Up to 6.4 GT/s Chipset - North Bridge: Intel 5520 chipset - South Bridge: Intel ICH10R chipset M e mo r y - 12 registered &...
  • Page 11: Getting Started

    Getting Started Onboard I/O Back Panel - 1 serial console port (RJ-45 jack) - 2 USB 2.0 ports - 2 Gigabit LAN jacks - 1 VGA port - 2 InfiniBand connectors Onboard Connectors - 2 USB 2.0 pinheaders (4 ports) - 1 serial port connector - 2 SMBus pinheaders Slot...
  • Page 12: Mainboard Layout

    M S-91C2 Server Board Mainboard Layout 5520 Master Series (MS-91C2 V1.X) Server Board...
  • Page 13: Chapter 2 Hardware Setup

    Hardware Setup Chapter 2 Hardware Setup This chapter provides you with the information about hardware setup procedures. While doing the installation, be careful in holding the components and follow the installation procedures. For some components, if you install in the wrong orientation, the components will not work properly.
  • Page 14: Quick Components Guide

    M S-91C2 Server Board Quick Components Guide FAN1, p.2-11 FAN2, p.2-11 FAN3, p.2-11 DIMM Slots, p.2-7 JPWR1, p.2-8 JPWR3, p.2-8 JPWR2, p.2-8 CPU, p.2-3 DIMM Slots, p.2-7 CPU, p.2-3 JFP1, p.2-13 J_SMBUS1, p.2-14 JUSB1~2, p.2-12 SATA1~4, p.2-10 FAN4, p.2-11 PCIE_SLOT1, p.2-16 JBAT1, p.2-15 J_SMLINK1, p.2-14 COM2, p.2-11...
  • Page 15: Cpu (Central Processing Unit)

    Hardware Setup CPU (Central Processing Unit) W hen you are installing the CPU, make sure that you install the cooler to prevent the CPU from overheating. If you do not have the CPU cooler, consult your dealer before turning on the computer. Important Overheating Overheating will seriously damage the CPU and system.
  • Page 16 M S-91C2 Server Board CPU & Cooler Installation W hen you are installing the CPU, make sure the CPU has a cooler attached on the top to prevent overheating. Meanwhile, do not forget to apply some thermal paste on CPU before installing the heat sink/cooler fan for better heat dispersion. Follow the steps below to install the CPU &...
  • Page 17: Hardware Setup

    Hardware Setup 5. Visually inspect if the CPU is seated 6. C over t h e l oad p l at e on t o t h e well into the socket. If not, take out package. the CPU with pure vertical motion and reinstall.
  • Page 18 M S-91C2 Server Board 9. Align the holes on the mainboard with 10. Turn over the mainboard to confirm the heatsink. Push down the cooler that the c lip-ends are c orrectly until its four clips get wedged into inserted. the holes of the mainboard.
  • Page 19: Memory

    Hardware Setup Memory These DIMM slots are intended for system memory modules. DDR3 240-pin, 1.5V 48x2=96 pin 72x2=144 pin Installing Memory Modules 1. Locate the DIMM slots on the mainboard. Flip open the retaining clip at each side of the DIMM slot. 2.
  • Page 20: Power Supply

    M S-91C2 Server Board Power Supply 20-Pin System Power Connector: JPWR1, JPWR3 This connector allows you to connect to a power supply. To connect the power supply, make sure the plug of the power supply is inserted in the proper orientation and the pins are aligned.
  • Page 21 Hardware Setup Back Panel I/O Serial Console Port USB Ports VGA Port InfiniBand Connectors Serial Console Port The serial port is a 16550A high speed communications port that sends/ receives 16 bytes FIFOs. You can attach a serial mouse or other serial devices directly to the connector.
  • Page 22: Connector

    M S-91C2 Server Board Connector Serial ATA Connector: SATA1 ~ SATA4 This connector is a high-speed Serial ATA interface port. Each connector can con- nect to one Serial ATA device. SATA1 SATA2 SATA3 SATA4 Important Please do not fold the Serial ATA cable into 90-degree angle. Otherwise, data loss may occur during transmission.
  • Page 23 Hardware Setup Serial Port Connector: COM2 This connector is a 16550A high speed communications port that sends/receives 16 bytes FIFOs. You can attach a serial device to it through the optional serial port bracket. Pin Definition SIGNAL DESCRIPTION COM2 Data Carry Detect Serial In or Receive Data SOUT Serial Out or Transmit Data...
  • Page 24 M S-91C2 Server Board Front USB Connector: JUSB1, JUSB2 ® This connector, compliant with Intel I/O Connectivity Design Guide, is ideal for con- necting high-speed USB interface peripherals such as USB HDD, digital cameras, M P3 players, printers, modems and the like. Pin Definition JUSB1, SIGNAL...
  • Page 25 Hardware Setup IPMB Connector: J_IPMB1 This connector is used to connect the IPMB (Intelligent Platform Management Bus) SMBus. Pin Definition J_IPMB1 SIGNAL IPMB_DATA IPMB_CLK Front Panel Connector: JFP1 This connector is designed for electrical connection to the front panel switches and LEDs.
  • Page 26 M S-91C2 Server Board I2C Bus Connector: J_SMBUS1, J_SMLINK1 This connector, known as I C, is for users to connect System Management Bus (SMBus) interface. J_SMBUS1 Pin Definition J_SMBUS1 SIGNAL SMBUS_ICH_DATA SMBUS_ICH_CLK SMBUS_ALERT# J-SMLINK1 Pin Definition J_SMLINK1 SIGNAL SM_LINK1 SM_LINK0 LINK_ALERT# 2-14...
  • Page 27: Jumper

    Hardware Setup Jumper BMC Flash Jumper: J_BMC_WP1 This jumper is used to enable/disable the BMC flash. W hen you intend to update the BMC code, uncap this jumper first. Under normal operation, we suggest that you disable the BMC flash by capping this jumper to protect the BMC from virus infection. J_BMC_WP1 Disable BMC Flash Enable BMC Flash...
  • Page 28: Slot

    M S-91C2 Server Board Slot PCI (Peripheral Component Interconnect) Express Slot The PCI Express slot supports the PCI Express interface expansion card. The PCI Express x16 slot supports up to 4.0 GB/s transfer rate. PCI Express x16 Slot Important When adding or removing expansion cards, make sure that you unplug the power supply first.
  • Page 29: Chapter 3 Bios Setup

    BIOS Setup Chapter 3 BIOS Setup This chapter provides information on the BIOS Setup program and allows you to configure the system for optimum use. You may need to run the Setup program when: ² An error message appears on the screen during the system booting up, and requests you to run SETUP.
  • Page 30: Entering Setup

    M S-91C2 Server Board Entering Setup Power on the computer and the system will start POST (Power On Self Test) process. W hen the message below appears on the screen, press <Del> key to enter Setup. Press Del to enter SETUP If the message disappears before you respond and you still wish to enter Setup, restart the system by turning it OFF and On or pressing the RESET button.
  • Page 31: Control Keys

    BIOS Setup Control Keys < -> Move to the previous item < ¯> Move to the next item < ¬> Move to the item in the left hand < ®> Move to the item in the right hand Select the item <Enter>...
  • Page 32: The Menu Bar

    M S-91C2 Server Board The Menu Bar Main Use this menu for basic system configurations, such as time, date etc. Advanced Use this menu to set up the items of special enhanced features. Boot Use this menu to specify the priority of boot devices. Security Use this menu to set supervisor and user passwords.
  • Page 33: Main

    BIOS Setup Main AM I BIOS, Processor, System M emory These items show the firmware and hardware specifications of your system. Read only. System Time This setting allows you to set the system time. The time format is <Hour> <Minute> <Second>.
  • Page 34: Advanced

    M S-91C2 Server Board Advanced CPU Configuration C1E Support W hen the C1E Support (Enhanced Halt Powerdown State) is enabled, the proc- essor will transition to a lower core to bus ratio and lower voltage ID driven by...
  • Page 35 BIOS Setup the processor to the voltage regulator before entering Halt Powerdown State (C1). Not all porcessors support Enhanced Halt Powerdown State (C1E). Hardware Prefetcher The processor has a hardware prefetcher that automatically analyzes its re- quirements and prefetches data and instructions from the memory into the Level 2 cache that are likely to be required in the near future.
  • Page 36 M S-91C2 Server Board Intel(R) TurboM ode Tech This item is used to enable/ disable Intel Robson technology. Intel Robson tech- nology is turbo memory technology that can let the users to enable operation system without accessing hard disk frequenctly. This boot up way can promote 20% speed and promote the speed of the large application program two times that can speed up the enable time and reduce power consumption.
  • Page 37 BIOS Setup 1st/ 2nd/ 3rd/ 4th IDE [Type] Press PgUp/<+> or PgDn/<-> to select [Manual], [None] or [Auto] type. Note that the specifications of your drive must match with the drive table. The hard disk will not work properly if you enter improper information for this category.
  • Page 38 M S-91C2 Server Board Super IO Configuration Serial Port 1 Address, Serial Port 2 Address Select an address and a corresponding interrupt for the serial port 1/2. ACPI Configuration 3-10...
  • Page 39 BIOS Setup Advanced ACPI Configuration ACPI Version Features This setting allows you to select the ACPI version. ACPI APIC Support This BIOS feature is used to enable or disable the motherboard's APIC (Advanced Programmable Interrupt Controller). The APIC provides multiprocessor support, more IRQs and faster interrupt handling.
  • Page 40 M S-91C2 Server Board Chipset ACPI Configuration High Performance Event Timer The High Precision Event Timer (HPET) was developed jointly by Intel and Microsoft to meet the timing requirements of multimedia and other time-sensitive applications. In addition to extending the capabilities and precision of a system, the HPET also improves system performance.
  • Page 41 BIOS Setup AHCI BIOS Support This BIOS feature controls the SATA controller's AHCI (Advanced Host Control- ler Interface) functionality. It is a new interface specification that enables ad- vanced SATA features like Native Command Queuing (NCQ) and hot-plugging. AHCI CD/DVD Boot Time Out This setting specifies the delay of the AHCI CD/DVD drivers loading for multi- read/write.
  • Page 42 M S-91C2 Server Board IPMI 2.0 Configuration Status of BM C, BM C Firmware Version These settings show the status of the BMC (Baseboard Management Controller) chip and its firmware version. Read only. View BM C System Event Log Use this function to view system event logs recorded by BMC. Clear BM C System Event Log Use this function to clear system event logs recorded by BMC.
  • Page 43 BIOS Setup BM C LAN1/ LAN2 Configuration Notify BMC IP Source Use this setting to check the BMC IP source. Current IP Address in BMC, Current Subnet Mask in BM C, Cur- rent Gateway in BM C Use these settings to view the IP address, subnet mask, and gateway in BMC.
  • Page 44 M S-91C2 Server Board FAN Control Type This item enables/disables the Smart Fan feature. Smart Fan is an excellent feature which will adjust the CPU fan speed automatically depending on the CPU current temperature, avoiding the overheating to damage your system. Remote Access Configuration Remote Access The setting enables/disables the remote access function.
  • Page 45 BIOS Setup host system and terminal(s). This setting specifies the type of terminal device for console redirection. VT-UTF8 Combo Key Support This setting enables/disables the VT-UTF8 combination key support for ANSI/ VT100 terminals. Sredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. APM Configuration Resume On RTC Alarm W hen [Enabled], your can set the date and time at which the RTC (real-time...
  • Page 46: Boot

    M S-91C2 Server Board Boot Boot Settings Configuration 3-18...
  • Page 47 BIOS Setup Quiet Boot This BIOS feature determines if the BIOS should hide the normal POST mes- sages with the motherboard or system manufacturer's full-screen logo. W hen it is enabled, the BIOS will display the full-screen logo during the boot-up sequence, hiding normal POST messages.
  • Page 48: Security

    M S-91C2 Server Board Security Supervisor Password / Change Supervisor Password Supervisor Password controls access to the BIOS Setup utility. These settings allow you to set or change the supervisor password. User Password / Change User Password User Password controls access to the system at boot. These settings allow you to set or change the user password.
  • Page 49: Chipset

    BIOS Setup Chipset CPU Bridge Configuration QPI Links Speed This item allows you to select the QPI links speed type. 3-21...
  • Page 50 M S-91C2 Server Board QPI Frequency This item allows you to select the QPI frequency. M emory Frequency This setting allows you to select the memory frequency. M emory M ode This setting specifies the memory mode. Demand Scrubbing, Patrol Scrubbing These settings support demand and patrol scrubbing to detect and repair memory problems.
  • Page 51 BIOS Setup North Bridge Information This sub-menu shows the north bridge information. South Bridge Configuration USB Functions This setting specifies the function of the onboard USB controller. 3-23...
  • Page 52 M S-91C2 Server Board Restore on AC Power Loss This setting specifies whether your system will reboot after a power failure or interrupt occurs. Available settings are: [Power Off] Leaves the computer in the power off state. [Power On] Leaves the computer in the power on state. [Last State] Restores the system to the previous status before power failure or interrupt occurred.
  • Page 53: Exit

    BIOS Setup Exit Save Changes and Exit Save changes to CMOS and exit the Setup Utility. Discard Changes and Exit Abandon all changes and exit the Setup Utility. Discard Changes Abandon all changes and continue with the Setup Utility. Load Optimal Defaults Use this menu to load the default values set by the mainboard manufacturer specifi- cally for optimal performance of the mainboard.
  • Page 54 This page is intentionally left blank. viii...
  • Page 55: Appendix A Intel Ich10R Sata Raid

    Intel ICH10R SATA RAID Appendix A Intel ICH10R SATA RAID This appendix will assist users in configuring and en- abling RAID functionality on platforms...
  • Page 56: Introduction

    M S-91C2 Server Board Introduction The ICH10R provides a hybrid solution that combines 6 independent SATAII ports for support of up to 6 Serial ATAII (Serial ATAII RAID) drives. Serial ATAII (SATAII) is the latest generation of the ATA interface. SATA hard drives deliver blistering transfer speeds up to 3 Gb/s.
  • Page 57: Bios Configuration

    Intel ICH10R SATA RAID BIOS Configuration The Intel Matrix Storage Manager Option ROM should be integrated with the system BIOS on all motherboards with a supported Intel chipset. The Intel Matrix Stroage Manager Option ROM is the Intel RAID implementation and provides BIOS and DOS disk services.
  • Page 58 M S-91C2 Server Board After pressing the <Ctrl> and <I> keys simultaneously, the following window will appear: (1) Create RAID Volume Select option 1 “Create RAID Volume” and press <Enter> key. The following screen appears. Then in the Name field, specify a RAID Volume name and then press the <TAB>...
  • Page 59 Intel ICH10R SATA RAID In the Disk field, press <Enter> key and the following screen appears. Use <Space> key to select the disks you want to create for the RAID volume, then click <Enter> key to finish selection. Then select the strip value for the RAID array by using the “upper arrow” or “down arrow”...
  • Page 60 M S-91C2 Server Board Important Since you want to create two volumes (Intel Matrix RAID Technology), this default size (maximum) needs to be reduced. Type in a new size for the first volume. As an example: if you want the first volume to span the first half of the two disks, re-type the size to be half of what is shown by default.
  • Page 61 Intel ICH10R SATA RAID (2) Delete RAID Volume Here you can delete the RAID volume, but please be noted that all data on RAID drives will be lost. Important If your system currently boots to RAID and you delete the RAID volume in the Intel RAID Option ROM, your system will become unbootable.
  • Page 62 M S-91C2 Server Board (3) Reset Disks to Non-RAID Select option 3 Reset Disks to Non-RAID and press <Enter> to delete the RAID volume and remove any RAID structures from the drives. The following screen appears: Press <Y> key to accept the selection. Important 1.
  • Page 63 Intel ICH10R SATA RAID (4) Recovery Volume Options Select option 4 Recovery Volume Options and press <Enter> to change recovery volume mode. The following screen appears: Recovery mode will change from Continuous Update to On-Request after you enable “Only Recovery Disk” or “Only Master Disk”.
  • Page 64: Installing Driver

    RAID Driver” for ® yourself. 1. Insert the MSI CD into the CD-ROM drive. 2. Click the “Browse CD” on the Setup screen. 3. Copy all the contents in \\SATA2_RAID\f6flpy3288 (32 bits) or \\SATA2_RAID\f6flpy6488 (64 bits) to a formatted floppy diskette.
  • Page 65 Intel ICH10R SATA RAID † Existing Windows Server 2008/2003 Driver Installation 1. Insert the MSI CD into the CD-ROM drive. 2. The CD will auto-run and the setup screen will appear. 3. Under the Server Drivers tab, click on SATA2 RAID Install.
  • Page 66: Installing Software

    For this reason, you cannot remove or un-install this driver from the system after installation; however, you will have the ability to un-install all other non-driver components. Insert the MSI CD and click on Intel Matrix Storage Manager under the Utility tab to install the software. Click on this item...
  • Page 67 Intel ICH10R SATA RAID The InstallShield Wizard will begin automatically for installation showed as following: Click on the Next button to proceed the installation in the welcoming window. A-13...
  • Page 68 M S-91C2 Server Board The window shows the components to be installed. Click Next button to continue. After reading the license agreement in the following window, click Yes button to continue. A-14...
  • Page 69 Intel ICH10R SATA RAID The following window appears to show the Readme File Information. It shows the system requirements and installation information. Once the installation is complete, the following window appears. A-15...
  • Page 70: Raid Migration Instructions

    M S-91C2 Server Board RAID Migration Instructions The Intel Matrix Storage Console offers the flexibility to upgrade from a single Serial ATA (SATA) hard drive to RAID configuration when an additional SATA hard drive is added to the system. This process will create a new RAID volume from an existing disk.
  • Page 71: Create Raid Volume From Existing Disk

    Intel ICH10R SATA RAID Create RAID Volume from Existing Disk To create a RAID volume from an existing disk, choose Action --> Create RAID Volume from Existing Hard Drive. The Create RAID Volume from Existing Hard Drive Wizard pops up to lead you for the following procedure.
  • Page 72 M S-91C2 Server Board (1) Configure Volume Here you can configure the new RAID volume by entering the volume name, selecting the RAID level and strip size. † RAID Volume Name: A desired RAID volume name needs to be typed in where the ‘Volume_0000’ text currently appears above.
  • Page 73 Intel ICH10R SATA RAID expensive (requiring read-in prior to write, in order to be able to calculate the correct parity information), or similar to RAID-1 writes. The write efficiency depends heavily on the amount of memory in the machine, and the usage pattern of the array.
  • Page 74 M S-91C2 Server Board (3) Select Member Hard Drive(s) Then select the member disk (the target disk) that you wish to use and then click “- -->” to move it to the Selected field. Then click Next to continue. Please note that the existing data on the selected hard drive(s) will be deleted permanently.
  • Page 75 Intel ICH10R SATA RAID (4) Specify Volume Size Specify the amount of available array space to be used by the new RAID volume. You may enter the amount in the space or use the slider to specify. It is recommended you use 100% of the available space for the optimized usage.
  • Page 76 M S-91C2 Server Board (6) Start Migration The migration process may take up to two hours to complete depending on the size of the disks being used and the strip size selected. A dialogue window will appear stating that the migration process may take considerable time to complete, meanwhile a popup dialogue at the taskbar will also show the migration status.
  • Page 77: Recovery Volume Creation

    Intel ICH10R SATA RAID Recovery Volume Creation A recovery volume can be created using either Basic mode or Advanced mode in the Intel Matrix Storage Console. Recovery Volume in Basic Mode Creation Important Creating a recovery volume will permanently delete any existing data on the drive selected as the recovery drive.
  • Page 78 M S-91C2 Server Board Recovery Volume in Advanced Mode Creation Important Creating a recovery volume will permanently delete any existing data on the drive selected as the recovery drive. Back up all important data before beginning these steps. To create a recovery volume in Advanced mode, use the following steps: (1) Open the Intel Matrix Storage Console.
  • Page 79 Intel ICH10R SATA RAID (6) Select a hard drive to be used as the master hard drive for the recovery volume. (7) Select a hard drive to be used as the recovery hard drive for the recovery volume. A-25...
  • Page 80 M S-91C2 Server Board (8) Select an update policy. (9) Select Finish to begin recovery volume creation. A-26...
  • Page 81: Degraded Raid Array

    Intel ICH10R SATA RAID Degraded RAID Array A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard drive members fails or is temporarily disconnected, and data mirroring is lost. As a result, the system can only utilize the remaining functional hard drive member. To re- establish data mirroring and restore data redundancy, refer to the procedure below that corresponds to the current situation.
  • Page 82 M S-91C2 Server Board 5. Exit Intel RAID Option ROM, and then reboot to W indows system. 6. W hen prompted to rebuild the RAID volume, click 'Yes'. 7. The Intel(R) Storage Utility will be launched. Right-click the new hard drive and select 'Rebuild to this Disk'.

Table of Contents