Fujitsu D3144 Technical Manual
Fujitsu D3144 Technical Manual

Fujitsu D3144 Technical Manual

Baseboard for primergy rx900 s2

Advertisement

Quick Links

Technical Manual - English
Baseboard D3144, CPUMEMR D3145,
PCIR D3146 for PRIMERGY RX900 S2
Technical Manual
Edition May 2011

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D3144

  • Page 1 Technical Manual - English Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2 Technical Manual Edition May 2011...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 4 Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
  • Page 5 Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 6 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 7: Table Of Contents

    Onboard connectors and indicators ....48 3.8.1.1 Baseboard D3144 ..... . 48 3.8.1.2 CPU Memory Riser (CPUMEMR) D3145 .
  • Page 8: Technical Manual D3144, D3145, D3146 (Rx900 S2

    External connectors and indicators ....55 3.8.3.1 Baseboard D3144 ..... . . 55 3.8.3.2 I/O board .
  • Page 9: Introduction

    DVDs, see Installation DVD of ServerView Suite - ServerView Software Products. You will find detailed information about the BIOS setup in the "D3144 BIOS Setup Utility for RX900 S2" manual. PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2.
  • Page 10 Introduction Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 11: Important Information

    Upgrade and Maintenance Manual of your server. CE conformity The system complies with the requirements of the EC directives 2004/108/EC regarding "Electromagnetic Compatibility" and 2006/95/EC "Low Voltage Directive". This is indicated by the CE marking (CE = Communauté Européenne). Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 12: Environmental Protection

    Important information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 13 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 14 Important information Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 15: Features

    Features Overview This section provides an overview of the key characteristics for the baseboard D3144, the CPU Memory Risers (CPUMEMRs) D3145, and the PCI Riser (PCIR) D3146. Processors Up to 8 Intel Xeon® E7-8xxx series (Westmere-EX) processors (up to ●...
  • Page 16 – 5x 1 GB 1000Base-T System LAN connectors – 1x 1 GB 1000Base-T Shared LAN connector – 1x 100 MB 100Base-TX Management LAN connector – I/O board: – 1x serial connector – 4x USB 2.0 connectors – 1x video connector Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 17 – PWM Control and Fan Tach Monitor – Voltage Level Monitor and Temperature Monitor – Real-Time Clock (RTC) – Two Watchdog Timers – System and Clock Control – Three Multi-Purpose Timers – Interrupt Controller Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 18 VT-c support as standard ● Adapter fault tolerance, Load Balancing and Switch fault tolerance in ● combination with existing GB PCIe card is supported, based on the functionality (SW Kit) of onboard GB LAN controllers. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 19 (e.g. VMware) or as a software dongle. The baseboard can be equipped with a Trusted Platform Module (TPM). This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 20 Features The TPM is activated via the BIOS system, see the "D3144 BIOS Setup Utility for RX900 S2" manual. CAUTION! – When using the TPM, note the program descriptions provided by the third party manufacturers. – You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions.
  • Page 21: Main Memory

    DDR channels and two DIMM memory modules are connected to each channel. The DIMM slot number is defined as 2 characters: First digit ("1" or "2") ● Sequence number within the same DDR3 channel Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 22 DDR channel number, and the DIMM memory module number within the same DDR channel. DIMM slot Millbrook DIMM memory module number identifier channel number within the number same DDR channel Table 2: DIMM memory module connection on the CPUMEMR Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 23: Dimm Slot Population Order

    2B + 2D + 2F + 2H 2A + 2C + 2E + 2G Table 3: DIMM memory module population order for an individual CPUMEMR B 1C B 2C Figure 1: DIMM slot population order for an individual CPUMEMR Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 24: Dimm Slot Population Rules For Differently Ranked Dimms

    1 rank 2 rank not installed 2 rank 2 rank 1 rank 1 rank 1 rank not installed 1 rank not installed not installed Table 4: Supported DIMM configurations with mixed DIMM RANK Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 25: Qpi Topology

    CPUs not included in this configuration are set to "disabled". As soon as the removed CPU has been reinstalled, the system enables all those disabled CPUs that are needed to form the next supported configuration. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 26 QPI scenarios depending on the position of the CPU that has been removed. Configurations with one to three CPUs are not to be understood as minimum configurations. They may occur due to the removal of CPUMEMRs. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 27 CPU#5 empty CPU#7 or #8 empty CPU#4 empty CPU#5 or #6 empty CPU#3 CPU#4 empty empty CPU#3 empty CPU#3 empty CPU#3 empty CPU#2 CPU#1 empty empty C1-2 C1-1 Figure 3: QPI topology transitions Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 28: Memory Configuration Modes

    DIMM# (1B, 1D, 1F, 1H) ● DIMM# (1A, 1C, 1E, 1G) ● DIMM# (2B, 2D, 2F, 2H) ● DIMM# (2A, 2C, 2E, 2G) ● B 1C B 2C Figure 4: Grouping of DIMM slots for memory mirroring Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 29 In a 6 or 8 CPUMEMR configuration, memory mirroring is configured between pairs of CPUMEMRs. Figure 6 shows the CPUMEMR mirroring pairs (1,2), (3,4), (5,6), (7,8) where each pair consists of a green and a light grey CPUMEMR. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 30 BIOS boots without mirroring configuration. 3. If the active DIMM memory modules form a valid mirroring configuration, the BIOS keeps mirroring configuration with the remaining DIMM memory modules. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 31: Hemisphere Mode

    Data is distributed over these two sections for better performance. As hemisphere mode is used for configurations with more than 4 CPUs, an even number of CPUs is necessary to configure memory-mirroring. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 32: Memory Interleaving

    CPUs and IOHs for 4, 6, and 8 CPUMEMRs. DIMM 4 CPUMEMRs 6 CPUMEMRs 8 CPUMEMRs slot pop. order CPU#1 1 CPU#2 1 CPU#3 0 Table 6: DIMM slot population order and mapping of DIMM slots to I/O Hubs and CPUs Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 33 6 CPUMEMRs 8 CPUMEMRs slot pop. order CPU#4 0 CPU#5 0 CPU#6 0 CPU#7 0 CPU#8 0 Table 6: DIMM slot population order and mapping of DIMM slots to I/O Hubs and CPUs Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 34: Pcie Slots

    CSS indicators (B) and (H). In addition, PCI hot-plug slots are equipped with the indicator (I). Figure 8: PCIe slots on the PCI Riser (A) and the baseboard (E; only PCI part is shown) Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 35: Pci Interrupt Assignment

    PCIe slots to the 4 I/O Hubs and the 4 - 8 CPUMEMRs. Before adding an expansion card, check carefully whether this PCIe slot is supported with the CPUMEMR configuration of the individual server. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 36 IOH#1 IOH#4 IOH#2 IOH#3 CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR Figure 9: Assignment of PCIe slots to CPUMEMRs Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 37 PCIe slot #12 hot-plug CPU#7 #7 or PCIe slot #17 Gen2x4 CPU#8 PCIe slot #13 PCIe slot #14 PCIe slot #15 PCIe slot #16 Table 7: Mapping of PCIe slots to I/O Hubs and CPUs Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 38: Expansion Card Configuration Table

    Gen 2 x8 8G-FCx2 Gen 2 x8 Intel GbEx1 Gen 1 x4 GbEx2 Gen1 x4 (D2735) GbEx4 Gen2 x4 (D2745) 10GbEx2 Gen2 x8 (D2755) Table 8: Expansion card installation recommendation I/O Hubs IOH#1 and IOH#2 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 39 PCIe Max # SAS 3Gb Gen1 x4 SAS 6Gb Geb 2 x6 Cougar2 Gen 2 x8 SAS RAID Gen 2 x8 (WASAT) Table 9: Expansion card installation recommendation I/O Hubs IOH#3 and IOH#4 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 40 PCI Riser when a BBU is connected because of limited length of the BBU cable. *2) No mix with FC controller possible. *3) Capacity: 160 GB, 320 GB, 640 GB *4) Capacity: 320 GB, 640 GB, 1280 GB Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 41: I/O Space

    I/O space requirements where "x" indicates that I/O space is required. Please note that I/O space assignment is only needed if Legacy LAN Boot(PXE, iSCSI) and an LSI SAS/SAS_RAID card is used. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 42: I/O Space Limitation

    Auto and Disabled can be selected in the BIOS setup menu to assign I/O space for onboard devices and for PCIe slots including slot #8 for the Modular RAID controller. Auto is set for all onboard devices and PCIe slots by default. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 43 Disabled: I/O space is not assigned even if the device requests for it. ● If you specify auto, the I/O space is assigned in descending order of the PCI-bus number within each I/O Hub until no I/O space is left. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 44 PXE-boot from Onboard- LAN as the Intel Boot Agent ROM requires I/O space. PCIe slot PCIe slot Table 11: I/O space assignment for 4, 6, and 8 CPU configurations Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 45 IOH #4 not Max 2 recognized recognized PCIe slot PCIe slot PCIe slot PCIe slot Max 16 Max 16 Max 16 Table 11: I/O space assignment for 4, 6, and 8 CPU configurations Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 46: Screen Resolutions

    Temperature monitoring Measuring the processor temperature and ambient temperature by way of a temperature sensor. Fan monitoring The fans are monitored. Fans that are blocked, sluggish or no longer available are detected. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 47: Connectors And Indicators

    S2’s Web interface or via the ServerView Operations Manager. Connectors and indicators This section provides an overview of: "Onboard connectors and indicators" on page 48 ● "External connectors and indicators" on page 55 ● Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 48: Onboard Connectors And Indicators

    Features 3.8.1 Onboard connectors and indicators 3.8.1.1 Baseboard D3144 Figure 11 shows the onboard connectors on the baseboard where the individual connectors are named in table Figure 11: Onboard connectors baseboard D3144 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 49 Front video connector (TPM) USB Flash Module (UFM) Front USB connector SATA optical disk drive CPU Memory Riser Table 13: Onboard connectors baseboard D3144 Figure 12 shows the indicators on the baseboard where the individual indicators are named in table Technical Manual...
  • Page 50 Features Figure 12: Indicators on the baseboard D3144 Pos. Indicator Pos. Indicator BMC heart beat PCI hot-plug power/fault POST code PCIe CSS Table 14: Connectors on the baseboard D3144 All the indicators are only visible after the cover has been removed.
  • Page 51: Cpu Memory Riser (Cpumemr) D3145

    CPUMEMR B 1C B 2C Figure 13: Onboard connectors and indicators CPUMEMR D3145 Pos. Connector Pos. Indicator DIMM, CPU, CPUMEMR CPUMEMR Table 15: Onboard connectors and indicators CPUMEMR D3145 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 52: Pci Riser (Pcir) D3146

    Figure 14: Onboard connectors and indicators PCIR D3146 Pos. Connector Pos. Indicator PCIe slots PCIe CSS PCIR CSS button Table 16: Onboard connectors and indicators PCIR D3146 Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 53: I/O Board

    Figure 15 shows the onboard connector on the I/O board. Figure 15: Onboard connector on the I/0 board Pos. Connector 1x USB connector For external connectors, please refer to "I/O board" on page Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 54: Onboard Dip Switch

    Switch 2 is used to define whether the boot password is skipped at system startup, if Password On Boot is set to First Boot or Every Boot in the BIOS Setup security menu. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 55: External Connectors And Indicators

    18. The LAN indicators are explained in table Figure 17: External connectors of the baseboard D3144 Pos. Port Connector Pos. Indicator 1x 100 MB Management Global error indicator...
  • Page 56 (indicator description table Table 18: External connectors on the baseboard D3144 The system is equipped with one Dual 10 GB Ethernet Controller type Intel 82599. In addition, three Dual 1 GB Ethernet Controller type Intel 82576 NS (system LAN) are installed supporting transmission rates of 10 Mbit/s, 100 Mbit/s, and (only for system LAN) 1 Gbit/s.
  • Page 57 Remains dark: LAN transfer rate of 10 Mbit/s. Activity LAN link/transfer Steady green signal: (shared LAN) LAN connection exists. Remains dark: no LAN connection exists. Flashes green: LAN transfer takes place. Table 19: LAN indicators Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 58 Remains dark: LAN transfer rate of 10 Mbit/s. Activity LAN link/transfer Steady green signal: (management LAN) LAN connection exists. Remains dark: no LAN connection exists. Flashes green: LAN transfer takes place. Table 19: LAN indicators Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 59: I/O Board

    Figure 19: External connectors on the I/O board Pos. Connector 4x USB Serial COM1 Video Table 20: External connectors on the I/O board The serial connector COM1 can be used as default interface or to communicate with the iRMC S2. Technical Manual D3144, D3145, D3146 (RX900 S2)
  • Page 60 Features Technical Manual D3144, D3145, D3146 (RX900 S2)

This manual is also suitable for:

Cpumemr d3145Pcir d3146

Table of Contents