Section B; Specifications; Section B Specifications - Toyotomi Oil Miser OM-148 Operation And Maintenance Instructions

Instantaneous oil-fired water heater type b
Table of Contents

Advertisement

SECTION B:

SPECIFICATIONS

Model:
Type:
Combustion Type
Flue Pipe
Heating Supply System
Source of Water
Ignition:
Fuel:
Efficiency:
Hot Water Input:
Fuel Consumption:
Capacity of Heat Exchanger:
Fuel system:
Dimensions (W x H x D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Required Accessories:
Safety Device:
Exhaust Air Temperature:
Nozzle:
Quantity of Vapor
Spraying Angle
Spray Pattern
Temperature Fuse:
Electric Current Fuse:
(1)
Heat and vaporized water are produced by the combustion process of this water heater. This rating
does not take into account heat loss due to condensation of water vapor.
(2)
External tank to be purchased from local suppliers.
SPECIFICATIONS
OM-148 (Type B)
Pressure Vapor
Forced Flue
Instantaneous
Direct Connection to Main Supply
High Voltage Discharge Spark
ASTM D3699 1-K Kerosene,
ASTM D396 No.1 or No.2 Fuel Oil
(1)
88%
148‚000 BTU/h
1.05 gal/h
5.10 gal
External tank
12-5/8'' x 27-3/4'' x 22-1/2''
86 lbs. Empty
4-3/4 diameter
10 ft., 3 bends or less
120 Volts AC, 60 Hz
Ignition - 120W
Burning - 98W
Fuel filter, Temp & pressure relief valve
Over-heat protector, Ignition safety device,
Heat exchanger bi-metal switch,
Temperature fuse, Fusible link valve
less than 500°F
0.85 GPH
60°
Delavan Type XA
282°F
5 A
(2)
4

Hide quick links: