Crown DCi 8|600N Operation Manual page 42

Dci series – network input models
Table of Contents

Advertisement

Advanced Operation
Input Level, Faders, Mute, Link, I/O Level Meters, and Indicators
This panel is on the left side of the DriveCore Install Network main control panel shown above. Channels 1, and 2 Level Controls set the input signal level of each channel.
Each channel can be muted, and both faders can be linked with the Link button.
Input Signal Level Meter (green)
The measurement range is from 0dBFS to –40dBFS with 0.5dB resolution. Each audio channel has the following monitors:
Switched Audio Input: This meter shows only the switched (selected) audio input after the Input Audio Router.
Clip Indicator
Peak + RMS levels
Output Signal Level Meter (blue)
The measurement range is from 0 dB to –40 dB with 0.5 dB resolution. The monitors are scaled so that 0 dB is referenced to the full rated output voltage of the amplifier.
The wider left meter is rms and the right meter is peak for each channel. An output clip indicator is provided.
Indicators
Temp: Lights if the temperature of the amplifier is too high and the amplifier is near shutdown.
Green: Thermal headroom used up is less than 59%.
Yellow: Thermal headroom used up is 60-80%.
Red: Thermal headroom used up is more than 81%.
Limit: Lights when the amplifier signal is being limited.
Load: Lights when the load impedance is out of range.
Ready: Lights when the amplifier is on and ready to supply power.
Fault: Lights when the amplifier is in a fault mode service may be required.
page 42
Figure 27
DriveCore Install Network Series Power Amplifiers
Operation Manual