Greenfloor stainless steel manifolds
All Greenfloor manifolds are manufactured from stainless
steel and include flow meters for accurate system
commissioning. A full range of accessories is available
including ball valves and connectors.
The pre-assembled stainless steel manifolds serve 2-16
zone applications. They are supplied with integrated valves
providing a filling and draining facility and automatic air
vents. In the event of additional zones being required,
manifolds can be joined together. The flow rate can be
accurately set on flow meters for safe and rapid setting
of the values provided by the Worcester Design Service.
The return manifold provides threaded connections for
installation of electronic actuators.
Height
Depth
Material
Flow meters
Flow & return heat source
Flow & return to underfloor zones (PE-Xc pipe)
Manifold cabinets
Greenfloor manifold cabinets are constructed from 1mm
galvanised sheet steel. The recessed type allow a flush
finish to a plastered wall and feature pre-punched side
openings for manifold connections and pipe penetrations
at the top and bottom. They are also height adjustable
to align with the screed thickness. A surface mounted
version is also available. Both the recessed and surface
mounted cabinets are lockable to prevent unauthorised access.
Manifold cabinets
Surface
VSS-A
mounted
560
Width
560mm
Height
700mm
Depth
150mm
VSS-U
Recessed
560
560mm
Width
Height
780-880mm 780-880mm 780-880mm 780-880mm
(adjustable)
Depth
115-165mm 115-165mm 115-165mm 115-165mm
(adjustable)
350mm
62mm
Stainless steel
Yes
1"
¾"
VSS-A
VSS-A
VSS-A
700
1000
700mm
1,000mm
1,300mm
700mm
700mm
700mm
150mm
150mm
150mm
VSS-U
VSS-U
VSS-U
700
1000
700mm
1,000mm
1,300mm
Note: for a two zone system, the manifold width is
200mm. For each additional zone added, the manifold
width increases by 50mm. The maximum number of
zones is 16.
1300
1300
7 7