10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
11
SERVICE
IF FAUCET DRIPS
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (5) inlets may cause reduced
flow in "full on" hot or cold. To clean inlets, first
turn off water supply, then:
Remove HANDLE (1), CAP (2) CARTRIDGE
SCREWS (3) RETAINER (4) and CARTRIDGE (5).
Clean inlets on CARTRIDGE (5).
Reassemble CARTRIDGE (5), RETAINER (4)
alternately tightening SCREWS (3), CAP (2)
and HANDLE (1). Check flow.
5
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Tighten
3
4
1
2
4
WASTE
OUTLET
2
HOT LIMIT SAFETY STOP
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP .
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP . Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
ADJUSTMENT WHEN
WATER IS TOO HOT
POINTER ON
HOT LIMIT STOP
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
4
1
5
2
"P" TRAP
"A"
"A"
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
RED RING HOT
LIMIT SAFETY
STOP
5 1 3 1 4 R e v . 1 . 3
3

Advertisement

loading