Kenwood TK-7160 Service Manual page 31

Vhf fm
Hide thumbs Also See for TK-7160:
Table of Contents

Advertisement

Item
Condition
4. RF
1) CH : RX center (Wide)
bandpass
CH : RX low (Wide)
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R517, F501, R519 and R526 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning : Do not transmit if step "1." is not complete.
4. Adjust of voltage can be done by tuning TC442.
Receiver Section
Item
Condition
1. Seisitivity 1) CH : RX low (Wide/Narrow)
CH : RX center (Wide/Narrow)
CH : RX high (Wide/Narrow)
2) SSG output
: –118dBm (0.28µV) (Wide)
: –116dBm (0.35µV) (Narrow)
Mod : 1kHz
Dev : ± 3.0kHz (Wide)
Dev : ± 1.5kHz (Narrow)
2. Squelch 9 1) CH : RX low (Wide)
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: 12dB SINAD+7dB
Mod : 1kHz
Dev : ± 3.0kHz (Wide)
Dev : ± 1.5kHz (Narrow)
3. Squelch 1 1) CH : RX low (Wide)
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: 12dB SINAD+2dB
Mod : 1kHz
Dev : ± 3.0kHz (Wide)
Dev : ± 1.5kHz (Narrow)
Transmitter Section
Item
Condition
1. Frequency 1) CH : TX center
2) Transmit
2. Maximum 1) CH : TX high
power
2) Transmit
limitting
ADJUSTMENT
Measurement
Test equipment
Terminal
Tra generator
ANT
Spectrum analyzer
BPF
Measurement
Test equipment
Terminal
SSG
ANT
Oscilloscope
EXT. SP
AF V.M
Distortion meter
Measurement
Test equipment
Terminal
Frequency counter
ANT
Power meter
Adjustment
Parts
Method
PC key
Adjust the BPF waveform
to Fig. 1
Adjustment
Parts
Method
Check
PC key
Adjust to open the squelch
Adjustment
Parts
Method
PC key
Adjust to center frequency
VR1
28W
TK-7160
Specifications/
Remarks
Specifications/
Remarks
SINAD
: 12dB or higher
Specifications/
Remarks
Within ± 100Hz
± 1W
31