Carrier Performance 15 48VR-A Owner's Information Manual page 8

2-stage packed hybrid heat dual fuel system with puron (r-410a) refrigerant single and three phase 2-5 nominal tons (sizes 24-60)
Hide thumbs Also See for Performance 15 48VR-A:

Advertisement

I
STEP1
STEP2
Fig. 7 - To Shut-off
Unit Electric
Cooling
MAINoN
"_
STEP3
A07797
To replace or inspect filters in accessory
filter rack (See Fig. 2):
1. Remove
the filter access panel using a 5/16-in.
nut driver.
2. Remove
the filter(s)
by pulling
it out of the unit. If the
filter(s) is dirty, clean or replace with a new one.
When installing
the new filter(s),
note the direction
of the airflow
arrows on the filter frame which
should
be pointing
at the indoor
coil.
3. Reinstall
filter
access
panel
ensuring
opening
is air and
water tight.
If you have difficulty
locating
your air filter(s)
or have questions
concerning
proper
filter
maintenance,
contact
your
dealer
for
instructions.
When
replacing
filters, always
use the same size and
type of filter that was supplied
originally
by the installer.
Fans and Fan Motors
Periodically
check
the condition
of fan wheels
and housings
and
fan motor
shaft
bearings.
Contact
your
dealer
for the
required
annual maintenance.
Heat Exchanger
To ensure
dependable
and efficient
heating
operation,
the heat
exchanger
should
be checked
by a qualified
maintenance
person
before
each
heating
season,
and cleaned
when
necessary.
This
checkout
should
not
be
attempted
by anyone
not
having
the
required
expertise
and equipment
to properly
do the job. Contact
your dealer for the required
periodic
maintenance.
Indoor and Outdoor
Coils
Cleaning
of the coils
should
only
be done
by qualified
service
personnel.
Contact
your
dealer
for
the
required
annual
maintenance.
Condensate
Drain
The drain
pan and condensate
drain
line should
be checked
and
cleaned
at the same
time the cooling
coils are checked
by your
dealer.
Compressor
All compressors
are factory
shipped
with
a normal
charge
of the
correct
type of refrigeration
grade
oil. A compressor
should
rarely
require additional
oil.
Condenser
(Outdoor)
Fan
PERSONAL
INJURY
AND
UNIT
DAMAGE
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury, death or property
damage.
Do not insert
sticks, screwdrivers,
or any other objects into
revolving
fan blades.
The
fan must
be kept free of all obstructions
to ensure
proper
cooling.
Contact
your dealer for any required
service.
Electrical
Controls
and Wiring
Electrical
controls
are
difficult
to
check
without
proper
instrumentation.
If there
are any discrepancies
in the operating
cycle,
contact your local dealer and request
service.
Refrigerant
Circuit
The refrigerant
circuit
is difficult
to check
for leaks
without
the
proper
equipment.
If inadequate
cooling
is suspected,
contact
your
local dealer for service.
EXPLOSION
AND ENVIRONMENTAL
HAZARD
Failure
to follow
this warning
could
result
in personal
injury, death or property
damage.
System
under
pressure.
Relieve
pressure
and
recover
all
refrigerant
before
system
repair
or final unit disposal.
Use
all
service
ports
and
open
all
flow-control
devices,
including
solenoid
valves.
Unit Panels
After performing
any maintenance
or service
on the unit,
be sure
all panels
are fastened
securely
in place
to prevent
rain
from
entering
unit cabinet
and to prevent
disruption
of the correct
unit
airflow pattern.
Combustion
Area and Vent System
For proper
and safe operation,
the furnace
needs air for combustion
and ventilation.
The air openings,
on the furnace,
the air openings
to the area in which the furnace
is installed,
and the spacing
around
the furnace must not be blocked
or obstructed.
The combustion
area and vent system
should be inspected
visually
before
each heating
season.
The normal
accumulation
of dirt, soot,
rust,
and
scale
can
result
in loss
of efficiency
and
improper