Download Print this page

Carrier Performance 15 48VR-A Owner's Information Manual page 3

2-stage packed hybrid heat dual fuel system with puron (r-410a) refrigerant single and three phase 2-5 nominal tons (sizes 24-60)
Hide thumbs Also See for Performance 15 48VR-A:

Advertisement

UNIT
INTRODUCTION
These
48VR-A
units
are small
packaged
gas heat/electric
heat
pump systems
that can utilize
the efficiency
of heat pump heating
and the comfort
of gas heating.
The system
will optinfize
for ideal
heating,
depending
on several factors. This unit
uses
Puron ®, the
ozone
friendly
refrigerant
for cooling
and heat pump heating.
Starting
or Shutting
Off Unit
NOTE:
Your combination
heating/cooling
unit is equipped
with
an automatic
direct spark ignition
and power
combustion
blower.
To start
unit gas heat:
Refer to Fig. 2 for location of unit front access panel. Refer to Fig.
3 for location
of gas valve. Refer
to Fig. 4 while
proceeding
with
the following
steps.
1. Set the temperature
selector
on room thermostat
to the low-
est temperature
setting and set system
switch
to Emergency
Heat.
2. Close the external
manual
gas shutoff valve.
3. Turn off the electrical
supply
to the unit.
4. Remove
the control
access panel with a 5/16-in.
nut driver.
(See Fig. 2.)
FIRE AND EXPLOSION
HAZARD
Failure
to follow
this
warning
could
result
in personal
injury, death, and/or property
damage.
1. If the main burners
fail to light,
or the blower
fails to
start, shut down gas heating
section
and call your dealer for
service.
2. Never attempt
to manually
light the main burners
on unit
with
a match,
lighter,
or any other
flame.
If the electric
sparking
device
fails to light the main burners,
refer to the
following
shutdown
procedures,
then
call your
dealer
as
soon as possible.
Filter Access
Panel
For Accessory
Filter Rack
Compressor
Access
Panel
Blower
Control
Access
Access
Panel
Panel
Fig. 2 - Unit Access
Panel
A09213
5. Move
the selector
switch
on the internal
gas valve
to the
OFF position
and wait 5 nfinutes.
6. Move the selector switch on the internal
gas valve to the ON
position.
7. Replace
the control
access panel.
8. Turn on the electrical
supply
to unit.
9. Open the external
manual
gas shutoff
valve.
10. Set the temperature
selector
on room
thermostat
slightly
above
room
temperature
to start unit.
The induced-draft
combustion
air fan will start. Main gas valve will open
and
main burners
should ignite within
25 seconds.
If the burner
does not light within
25 seconds,
the ignition
module
will
go into a Retry
Mode
after a period
of approximately
20
seconds
(following
the 7-second
ignition
period).
If the
burners
do not light by the 4 th ignition
try of the initial call
for heat, there is a lockout.
11. Set the temperature
selector
on room thermostat
to desired
setting.
Flue Hood
Burners
Gas Valve
A09043
Fig. 3 - Gas Heating/Electric
Cooling
Unit with Access
Panel
Removed
To shut off unit gas heat:
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this
warning
could
result
in personal
iniury, death, and/or property
damage.
Do
not turn off the electrical
power
to unit without
first
turning
off the gas supply.
NOTE:
If the unit is being
shut down
because
of a malfunction,
call your dealer as soon as possible.
Should
overheating
occur or the gas supply
fail to shut off, shut
off the
external
manual
gas valve
to the unit before
shutting
off
the electrical
supply. Do not use this unit if any part has been under
water. Immediately
call a qualified
service
technician
to inspect the
unit
and to replace
any part of the control
system
and any gas
control
which has been under water.
Refer to Fig. 5 while proceeding
with the following
steps.
1. Set
the temperature
selector
on room thermostat
to lowest
temperature
setting and set system
SWITCH
to OFF.
2. Close the external
manual
shutoff valve.
3. Turn off the electrical
power
supply to the unit.
4. Remove
the control
access panel. (See Fig. 2.)
5.
Move
the selector
switch
on the internal
gas valve
to the
OFF position.
6. Replace
the control access panel.

Advertisement

loading

This manual is also suitable for:

Performance 1548vr-a