Table Of Contents; Introduction; General Information - Superior BBV-36RMN Installation Instructions Manual

Standard series 36" b-vented gas appliances
Table of Contents

Advertisement

TABLE OF CONTENTS

Introduction ..................................... page
General Information ......................... page
Location .......................................... page
Clearances ....................................... page
Appliance Specifications .................. page
Gas Vent Rule .................................. page
Framing Specifications .................... page
Installation ....................................... page
Vent System Installation .................. page
Field Wiring ..................................... page
Connecting Gas Line ........................ page
Outside Air Kit Installation ............... page
Log and Rockwool Installation ........ page
Appliance Operation ........................ page
Manual Limit Switch ........................ page
Adjustments .................................... page 10
Finishing Requirements ................... page 10
Cold Climate Insulation .................... page 11
Installation Accessories ................... page 11
Gas Conversion Kits .................. page 12
This installation manual will help you obtain a
safe, efficient, dependable installation for your
appliance and vent system.
Please read and understand these
instructions before beginning your
installation.

INTRODUCTION

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.
2
The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
2
safe, efficient operation. External electrical
2
power is required to operate these units.
3
These appliances comply with National Safety
3
Standards and are tested and listed by War-
4
nock Hersey (Report No. J99025850) to ANSI
4
Z21.50 - 2000 (in Canada, CSA 2.22 - 2000),
and CAN/CGA-2.17-M91 in both USA and
5
Canada, as vented gas fireplaces.
5
5
Installation must conform to local codes. In the
absence of local codes, installation must com-
6
ply with the current National Fuel Gas Code,
7
ANSI Z223.1 (NFPA 54). (In Canada, the cur-
7
rent CAN/CGA B149 installation code.) Electri-
7
cal wiring must comply with local codes. In the
absence of local codes, installation must be in
8
accordance with the National Electrical Code,
9
NFPA 70 - (latest edition). (In Canada, the
9
current CSA C22.1 Canadian Electric Code.)
9
DO NOT ATTEMPT TO ALTER OR MODIFY
9
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instruc-
tions d'installation et d'utilisation qui
accompagnent l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WARNING: THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade the
performance of this system and may be dan-
gerous.
Input of appliance is 24,000 BTU/HR.
Gas
Orifice
Type
Size
Elevation
0 - 4500'
#42
Natural
(0 - 1370 m)
(.0935)
0 - 4500'
Propane
(.058)
(0 - 1370 m)
Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas mod-
els and 10 inches water column (2.49 kPa) for
propane gas models.
Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the con-
trol system and any gas control which have
been under water.
Ne pas se servir de cet appareil s'il a été
plongé dans l'eau, complètement ou en partie.
Appeler un technicien qualifié pour inspecter
l'appareil et remplacer toute partie du système
de contrôle et toute commande qui ont été
plongés dans l'leau.
This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes. This appliance is
only for use with the type of gas indicated
on the rating plate. This appliance is not con-
vertible for use with other gases, unless a
certified kit is used.
Cet appareil peut être installé dans un
maison préfabriquée (É.-U. seulement) ou
mobile déjà installée à demeure si les
réglements locaux le permettent. Cet
appareil doit être utilisé uniquement avec
les types de gaz indiqués sur la plaque
signalétique. Ne pas l'utiliser avec
d'autres gaz sauf si un kit de conversion
certifié est installé.