Part 2 Specifications - Cobra C6 Installation And Operation Manual

Gas cooktops 600mm & 900mm
Table of Contents

Advertisement

Model Covered in this Specification -
C6D [1] Cooktop
4 Open Burners.
C6C [1] Cooktop
2 Burners + 300 mm Griddle.
C6B
Cooktop
600 mm Griddle.
C9D [1] Cooktop
6 Open Burners.
C9C [1] Cooktop
4 Burners + 300 mm Griddle.
C9B [1] Cooktop
2 Burners + 600 mm Griddle.
C9A
Cooktop
900 mm Griddle.
[1] - Open Burner Options:-
F - With Flame Failure Protection.
- Standard Burners.
General
A heavy duty, high efficiency Cooktop for modular
kitchens. It has a high option Cooktop / Griddle
arrangement and is available on adjustable front
feet and robust rear rollers. Five griddle options with
2 models of base unit are available. Fitted with
'Individual Flame Failure' Option (F) for each open
burner. (Standard for UK - Optional for Non UK)
Griddles are fitted with pilot, flame failure and piezo
ignition as standard. These cooktops have an easy
clean stainless steel external finish.
Gas Supply Requirements
- Non - UK Only:
Input Rate (N.H.G.C.)
Supply Pressure
Burner Operating Pressure
Gas Connection
- UK Only:
Nominal
Heat Input (net)
Reduced
Nominal
Gas Rate (net)
Reduced
Supply Pressure
Burner Operating Pressure
Gas Connection
Part 2
Specifications
Natural Gas
Open Burner
Griddle
(each)
(each 300 mm
section)
22 MJ/hr
20 MJ/hr
(20,000 Btu/hr)
(18,956 Btu/hr)
1.13 - 3.40 kPa
(4.5" -13.5" w.c.)
1.0 kPa (*)
(4.0" w.c.)
¾" BSP Male
Natural Gas
(G20)
Open Burner
Griddle
(each)
(each 300 mm
section)
5.0 kW
5.0 kW
1.7 kW
1.5 kW
0.53 m
/hr
0.53 m
/hr
3
3
0.18 m
/hr
0.16 m
/hr
3
3
20 mbar
10 mbar (*)
¾" BSP Male
NOTE: (*)
*
- The burner operating pressure is to be measured
at the manifold test point with two burners
operating at full setting. The operating pressure
is ex-factory set, through the appliance regulator
and is not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer
to the 'Gas Conversion Instruction Sheet' for this
appliance for further details).
Gas Connection
Gas supply connection point is located at the rear
of the appliance, approximately 130 mm from the
right hand side and 630 mm from the floor. It is
reached from beneath the appliance. (Refer to the
'Dimensions' section).
Connection is ¾" BSP male thread (for all models).
LP Gas (Propane)
Open Burner
Griddle
(each)
(each 300 mm
section)
22 MJ/hr
20 MJ/hr
(20,000 Btu/hr)
(18,956 Btu/hr)
2.75 - 4.50 kPa
(11" -18.0"w.c.)
2.6 kPa (*)
(10.0" w.c.)
Propane
(G31)
Open Burner
Griddle
(each)
(each 300 mm
section)
4.6 kW
5.0 kW
1.5 kW
2.2 kW
0.36 kg/hr
0.39 kg/hr
0.12 kg/hr
0.17 kg/hr
37 mbar
28 mbar (*)
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9C6dC6cC6bC9dC9c ... Show all