KitchenAid KFGS306VSS Technical Education page 31

Flush-mount gas cooktop
Hide thumbs Also See for KFGS306VSS:
Table of Contents

Advertisement

5.
For LP gas conversion:
Completely tighten screw "A" to set the
minimum flame height.
For Natural gas conversion:
Tighten screw "A" to reduce flame height.
Loosen screw to increase flame height. See
"Complete Burner Adjustment" section.
A
A. Inner crown adjustment screw
B. Outer crown adjustment screw
6.
Replace the control knob.
To Adjust Outer Crown Flame:
1. Set the outer crown flame to LO.
2.
Remove the control knob.
3.
For LP gas conversion:
Completely tighten screw "B" to set the
minimum flame height.
For Natural gas conversion:
Tighten screw "B" to reduce flame height.
Loosen screw to increase flame height. See
"Complete Burner Adjustment" section.
4.
Replace the gray shield. Use a screwdriver
to help push the shield into place.
5.
Replace the black rubber grommet.
6.
Replace the control knob.
7. Test the flame by turning the control from
LO to HI, checking the flame at each
setting.
B
Complete Burner Adjustment
1. Check burner flame(s) for proper size and
shape. The cooktop "low" burner flame
should be a steady blue flame approxi-
mately 1/4" (0.64 cm) high.
A
B
2. Completely fill out the conversion label and
attach label to bottom of the cooktop next
to the rating tag. Do not cover the rating
tag with the conversion label.
3. Save the orifices removed from the cook-
top along with these instructions for future
reference.
Read "Sealed Surface Burners" section in
the Use and Care Guide supplied with your
cooktop.
2-21
A. Low flame
B. High flame

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfgu706vssKfgs366vssKfgu766vss

Table of Contents