Heat & Glo 8000CF-OAK-IPI Owner's Manual

Installation and operation
Hide thumbs Also See for 8000CF-OAK-IPI:
Table of Contents

Advertisement

Models:
8000CF-OAK-IPI
8000CFLP-OAKIPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 8000CF-OAK-IPI

  • Page 1 fi tter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2: Congratulations

    (Po. Col. d’eau) IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Junction Box Installation......45 F. Wall Switch Installation for Fan (Optional) ... . 45 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 4 D. Contact Information ......62 = Contains updated information. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 5: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 4021-645A 09-01-08...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compli- ance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Maximum Minimum Model...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 9: User Guide

    fi re or injury. DECORATIVE DOORS (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.I. FAN KIT SECTION 2.C HEARTH CLEAR SPACE SECTION 2.D. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 MANTEL...
  • Page 10: Fan Kit (Optional)

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 11: Lighting Instructions (Ipi)

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 LIGHTING INSTRUCTIONS (IPI) 1. Turn off all electric power to the appliance.
  • Page 12: After Fireplace Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/OFF is turned off. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 SOLUTIONS...
  • Page 13: Maintenance And Service

    If not using your fi replace for an extended period of time (summer months, vacations/trips, etc), to prevent unin- tended operation: • Remove batteries from remote controls. • Unplug 3 volt adapter plug on IPI models. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sense rod. Replace pilot as necessary. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 16: Installer Guide

    VENT PIPE IF ATTIC IS INSULATED (SECTION 8.D) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 HORIZONTAL TERMINATION CAP (SECTION 10.M )
  • Page 17: Design And Installation Considerations

    DO NOT use this appliance if any part has been under water. Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 18: Framing And Clearances

    NOTICE: Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference. 55-7/8 1419 2007 1219 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 MINIMUM 38-7/8 19-3/4...
  • Page 19: Constructing The Appliance Chase

    * MINIMUM FRAMING DIMENSIONS Rough Clearance Combustible Opening Combustible Floor to Ceiling (Width) 1245 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 FROM TOP OF HOOD TO CEILING Floor to Top Behind Sides of of Access Flooring Appliance...
  • Page 20: Mantel And Wall Projections

    Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Combustible Mantel Legs or Wall Projections Figure 5.4 Combustible Mantel Leg or Wall Projections 12-1/4 11-1/8 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 1 in. MIN. TOP VIEW 3 in. 3 ft.
  • Page 21: Termination Locations

    NEED TO BE INCREASED. REFER TO THE INSTALLATION INSTRUCTIONS SUPPLIED WITH THE DECORATIVE CAP COVER. Figure 6.3 Leveled Termination Caps Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 DIRECT VENT GAS, WOOD OR FUEL OIL TERMINATION Minimum Dimensions Wood &...
  • Page 22 Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 (See Note 2) Measure vertical clearances from this surface.
  • Page 23: Vent Information And Diagrams

    • Vertical terminations are measured to bottom of termination cap. • Horizontal pipe installed level with no rise. Figure 7.2 DVP Pipe Effective Length Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Vertical 8-1/2 in. Horizontal Effective Length...
  • Page 24: Vent Diagrams

    E. Vent Diagrams Top Vent - Horizontal Termination One Elbow Figure 7.3 Two Elbows Figure 7.4 INSTALLED HORIZONTALLY Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Minimum Maximum 1 ft.. 305 mm 3 ft.. 914 mm 2 ft..
  • Page 25 2 ft. 610 mm 6 ft. 3 ft. 914 mm 9 ft. = 50 ft. (15.2 m) Max. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Min. 914 mm 2 ft. 610 mm 6 ft. 1.8 m 4 ft.
  • Page 26 Figure 7.9 3. Center the fl ue restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). Figure 7.10 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 BREAK HERE - CHART -...
  • Page 27 2 ft. 610 mm 6 ft. 4 ft. 1.2 m 12 ft. INSTALLED HORIZONTALLY Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Maximum 3 ft. 914 mm 6 ft. 1.8 m 12 ft. 3.7 m = 50 ft. (15.2 m) Max.
  • Page 28: Vent Clearances And Framing

    3 to 4 inches between the pipe and shield. Figure 8.4 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 COMBUSTIBLE SURFACE 3 IN. MIN.
  • Page 29: Wall Penetration Framing

    1 inch above the center of the horizontal vent pipe. With minimum vertical or 12 inch and 90º elbow. Figure 8.6 Wall Penetration Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 12 in. 10 in.
  • Page 30: Install The Ceiling Firestop

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING Figure 8.8 Installing the Attic Shield Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 ATTIC ABOVE PIPE 10 in. (254 mm) INSTALL ATTIC INSULATION SHIELDS...
  • Page 31: Install Attic Insulation Shield

    BEND ALL TABS INWARD 90° TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE Figure 8.9 Attic Insulation Shield Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 BEND 3 TABS OUTWARD TO FASTEN TO CEILING FIRESTOP-BEND REMAINING TABS...
  • Page 32: Appliance Preparation

    Once the electrical and gas lines are hooked up, the lower access panel must be put back on the unit. NAILING Figure 9.3 SHEETROCK LEDGE CLEARANCE SLOT Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 LOWER ACCESS PANEL...
  • Page 33: Securing And Leveling The Appliance

    fi replace wrap. Using 2 self-tapping screws from the manual bag secure the gasket to the outer wrap (see Figure 9.5). FIRST VENT COMPONENT FIBERGLASS GASKET OUTERWRAP Figure 9.5 Fiberglass Gasket Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 34: Completing Grate Set-Up

    Figure 9.7 Re-install grate in unit F. Checking Pilot Plate Note: Ensure pilot plate is in place. This will ensure pilot stability (see Figure 9.8) STRAIGHTEN TO REMOVE GRATE Figure 9.8 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 PILOT PLATE...
  • Page 35: Installing Vent Pipe

    Figure 10.1 High Temperature Silicone Sealant Figure 10.2 Note: unintentional disconnection. Figure 10.4 Seams Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Lances Lances Figure 10.3 Make sure that the seams are not aligned to prevent CORRECT...
  • Page 36: Assemble Slip Sections

    DO NOT allow vent to sag below connection point to appliance. Pilot hole Pilot hole Figure 10.8 Securing Vertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 120º 120º...
  • Page 37: Disassemble Vent Sections

    Figure 10.11. • Pull carefully to separate the pieces of pipe. Figure 10.10 Rotate Seams for Disassembly Figure 10.11 Align and Disassemble Vent Sections Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 38: Install Metal Roof Flashing

    Figure 10.16 Assembling the Storm Collar Figure 10.16 Assembling the Storm Collar Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 CAULK...
  • Page 39: Install Rf4-8

    Figure 10.21 Slide Flashing Down, Secure & Apply Sealant SILICONE SEALANT (TOP OF BOOT) FLASHING OVER SHINGLES Figure 10.22 Installation Complete Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 APPLY SEALANT TOP & PARTIAL SIDES SHINGLES TRIMMED SHINGLES OVER FLASHING...
  • Page 40: Install Vertical Termination Cap

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 41: Install Horizontal Termination Cap

    DVP-TRAP2 can adjust 4 in. (6-9/16 to 10-9/16) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 HEAT SHIELD OR EXTENDED HEAT SHIELD...
  • Page 42: Gas Information

    • In the USA: Reduce burner orifi ce 4% for each 1000 feet above 2000 feet. • In CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 43: Electrical Information

    Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 44: Electrical Service And Repair

    CAN BE PLUGGED INTO ANY OF #1-#5 LOCATIONS ON THE NEUTRAL SIDE TRANSFORMER 3 VAC PLUG IN Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 INTERMITTENT PILOT IGNITOR * GROUND TO FIREPLACE CHASSIS PIGGYBACK ON/OFF SWITCH VALVE...
  • Page 45: Junction Box Installation

    (1/4 in. male) as shown. Figure 12.2 Junction Box Detail Junction Box Figure 12.3 Junction Box Wired to Wall Switch or BC10 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Romex Connector Cover Plate outside firebox...
  • Page 46: Finishing

    NON-COMBUSTIBLE 1 in. Figure 13.3 Noncombustible Facing Diagram MIN. 3 ft. MAX. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 FINISH WALL MATERIAL MAY BE COMBUSTIBLE - TOP AND SIDES BOARD 0 in. 0 in. 0 in.
  • Page 47: Appliance Setup

    Remove steel false base pan. Remove valve assembly. Disconnect fan and remove it through the valve assembly cavity. Figure 14.1 REMOVE FAN THROUGH VALVE ASSEMBLY CAVITY Figure 14.2 Figure 14.3 Rheostat Location Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 RHEOSTAT...
  • Page 48: Install The Optional Refractory

    Use this material to give the appliance a realistic ash bed. • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 49: Install The Log Assembly

    STEP 3: log 1. The bottom notch on log #2 must mate over the log tab on the burner face. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Log Assembly: LOGS-8OAK LOG TABS Remove metal grate supports (A) and refractory...
  • Page 50 Rest right end of log so that it engages tab on log 3. Log 2 may need to shift to right slightly. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 51: Fixed Glass Assembly

    Note: The adjustable air shutter is not offered with the LP model. The LP is fi xed, full open, for maximum primary air. Figure 14.6 Air Shutter Air Shutter Settings Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 AIR SHUTTER WING NUT Burner 3/8 in.
  • Page 52: Troubleshooting

    .17 in. or 1/8 in. (3 mm). Verify module is securely grounded to metal chassis of appliance. Verify battery voltage is at least 2.7 volts. Replace batteries if volt- age is below 2.7. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Corrective Action...
  • Page 53 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Corrective Action...
  • Page 54: Reference Materials

    ACCESS Location Figure 16.1 Appliance Dimensions Location Inches Millimeters 35-1/2 17-3/4 21-1/2 1015 9-1/8 2-1/4 4-1/8 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 ELECTRICAL ACCESS Inches Millimeters 23-1/2 39-1/4 1091 1221 34-1/4 46-3/4 1186 2-1/4 5-1/4...
  • Page 55: Vent Components Diagrams

    DVP-FS (Ceiling Firestop) 1- 1/2 in. (38 mm) 14 in. (356 mm) 12 in. (305 mm) Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 10-1/2 in. (267 mm) 4-7/8 in. ( 276 mm) 10-7/8 in. (276 mm) DVP45 (45º...
  • Page 56 DVP-TRAP1 DVP-TRAPK1 Figure 16.3 DVP vent components 8 in. Heat (203 mm) Shield Effective Length Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 Minimum Maximum Term Cap Effective Length Effective Length 3-1/8 in. 4-5/8 in. Trap1 79 mm 117 mm 5-3/8 in.
  • Page 57 7-1/8 in. (181 mm) 5-3/4 in. (146 mm) 13-7/8 in. (352 mm) 14 in. (356 mm) Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 31 in. (787 mm) 24-5/8 in. 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak 11-7/8 in.
  • Page 58 DVP-TB1 BasementVent Cap 12 in. 305 mm 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 7-3/8 in. (187 mm) 17-3/4 in. (451 mm) 3-7/8 in. 10-1/2 in. DVP-TV Vertical Termination Cap...
  • Page 59: Log Set Assembly

    8000CF-OAK-IPI C. Service Parts Service Parts Diagram Beginning Manufacturing Date: Jan. 2005 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08...
  • Page 60: Service Parts List

    Pilot Orifi ce LP Additional service part numbers appear on following page. Pre 002927628 Post 002927628 Pre 002927628 Post 002927628 Pre 002927628 Post 002927628 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 8000CF-OAK-IPI COMMENTS PART NUMBER LOGS-8OAK SRV2057-720 SRV2057-721 SRV2057-722...
  • Page 61 Note: Shutter sleeve not used on LP models Pre 002927628 Post 002927628 Pre 002927628 Post 002927628 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 8000CF-OAK-IPI Beginning Manufacturing Date: Jan. 2005 Ending Manufacturing Date: ______ COMMENTS PART NUMBER 4021-025...
  • Page 62: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2008 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 • Leave this manual with party responsible for use and operation.

This manual is also suitable for:

8000cflp-oakipi

Table of Contents