Technical Specifications - HP Compaq dc7600 Quickspecs

Business pc
Hide thumbs Also See for Compaq dc7600:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

Unit Environment and
Unit Environment and
Unit Environment and
Unit Environment and
Operating Conditions
Operating Conditions
Operating Conditions
Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
*NOTE:
NOTE:
NOTE:
NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options
installed.
Power Supply
Power Supply
Power Supply
Power Supply
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
Heat Dissipation
Power Supply Fan
Energy Star Compliant
Blue Angel Compliant
(<5w in S5 – Power Off)
FEMP Standby Power Compliant
(<2W in S5 – Power Off)**
Power Consumption in ES Mode
– Suspend to RAM (S3) (Instantly
Available PC)
Environmental and Mechanical
Engineering Support Center
(EMESC) – Intranet Web Site only
**NOTE:
**NOTE:
**NOTE: Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake
**NOTE:
on LAN" feature disabled in F10 Setup (default is "enabled").
Ultra-Slim Desktop
Ultra-Slim Desktop
Ultra-Slim Desktop
Ultra-Slim Desktop
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Ultra-Slim Desktop
Ultra-Slim Desktop
Ultra-Slim Desktop
Ultra-Slim Desktop
200 watt custom power supply –
Active PFC)
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
4A
Typical 340 btu/hr
(86 kg-cal/hr)
Maximum 1050 btu/hr
(265 kg-cal/hr)
70mm variable speed
X
X
X
< 3W
http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm
DA - 12253
North America — Version 36 — January 30, 2007
HP Compaq dc7600 Business PC
HP Compaq dc7600 Business PC
HP Compaq dc7600 Business PC
HP Compaq dc7600 Business PC
Small Form Factor
Small Form Factor
Small Form Factor
Small Form Factor
Operating: 50° to 95° F (10° to 35° C)*
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
Small Form Factor
Small Form Factor
Small Form Factor
Small Form Factor
240 watt custom power supply –
Active PFC
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
5A
Typical 340 btu/hr
(86 kg-cal/hr)
Maximum 1260 btu/hr
(318 kg-cal/hr
80mm variable speed
X
X
X
< 3W
Convertible Minitower
Convertible Minitower
Convertible Minitower
Convertible Minitower
Convertible Minitower
Convertible Minitower
Convertible Minitower
Convertible Minitower
365 watt custom power supply –
Active PFC)
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
6A
Typical 375 btu/hr
(95 kg-cal/hr)
Maximum 1916 btu/hr
(483 kg-cal/hr)
92mm variable speed
X
X
X
< 3W