Advertisement

Quick Links

Snapshot
SkyScan™ 4000
OK on Dimmer
For Use in Dry
Outdoor Location
For Use in Wet
Outdoor Location
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
Duty Cycle

USER MANUAL

5200 NW 108th Avenue Sunrise, FL 33351 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet SkyScan 4000

  • Page 1: User Manual

    Snapshot SkyScan™ 4000 OK on Dimmer For Use in Dry Outdoor Location For Use in Wet Outdoor Location Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse Duty Cycle USER MANUAL 5200 NW 108th Avenue Sunrise, FL 33351 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS 1. Before You Begin ..........................3 What is included ............................3 Unpacking Instructions ..........................3 AC Power ..............................3 Safety Instructions ............................ 4 2. Introduction ............................5 Features ..............................5 Product Overview............................5 3. Setup ..............................6 Lamp ................................
  • Page 3: Before You Begin

    1. B EFORE EGIN What is included Ø 1 x SkyScan™ 4000 Ø 1 x Power connector (no cable) Ø 1 x Warranty Card Ø 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition.
  • Page 4: Safety Instructions

    There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. SkyScan™ 4000 User Manual 1/30/2012 4:39 PM...
  • Page 5: Introduction

    2. I NTRODUCTION Features · Professional 4000W search light · Motorized pan: 120° / manual tilt: 40° · Quad power switches control lamp’s intensity (1k, 2k, 3k, or 4k) · Silent, hot-restrike ignition · Variable mechanical zoom · Ingress Protection: IP33 Product Overview Front lens...
  • Page 6: Setup

    3. S ETUP Lamp The lamp for this fixture arrives installed at the factory. Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with alcohol and wipe it with a lint free cloth before installation.
  • Page 7: Mechanical Installation

    WARNING! Note: please be sure to adhere to the following instructions and cautions before installing/servicing this lamp. Mechanical installation Because of their high luminance, UV radiation and internal pressure in both the hot and cold state, Xenon lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Always use the safety covers supplied when handling Xenon lamps.
  • Page 8: Fuse Replacement

    Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a Phillips #2 screwdriver, unscrew the fuse holder from its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its place and reconnect power.
  • Page 9: Operating Instructions

    4. O PERATING NSTRUCTIONS Pan motor Operation switch Power Indicator Fuse (X4) 15A 250V Lamp power switch (X4) T O T URN T HE PO WER T O T HE L AMP O N Using the 4 lamp power switches, select one at a time, in combination, until you reach the desired light output.
  • Page 10 T O ADJUST T HE Z O O M OF T HE F I XT URE Locate the “ZOOM” adjustment of the fixture, highlighted in the diagram below. Turn the adjustment knob clockwise to increase the beam angle. Turn the adjustment knob counter-clockwise to decrease the beam angle. Zoom adjustment knob SkyScan™...
  • Page 11: General Troubleshooting

    ü power the fixture and it will automatically enter into this mode If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location on the next page. SkyScan™ 4000 User Manual 1/30/2012 4:39 PM...
  • Page 12: Contact Us

    Contact Us Wo rl d Wi d e General Information CHAUVET 5200 NW 108th Avenue Sunrise, FL 33351 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084 Technical Support CHAUVET 5200 NW 108th Avenue Sunrise, FL 33351 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
  • Page 13: Appendix

    Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
  • Page 14: Technical Specifications

    Technical Specifications WEIGHT & DIMENSIONS Length ..........................27 in (686 mm) Width ........................... 27 in (686 mm) Height ..........................43.5 in (1,105 mm) Weight ..........................174 lbs (79 kg) POWER AC Power ........................... 230V 50Hz Fuse ............................. 15A 250V (4X) Power Consumption &...

Table of Contents