Replacing The Cutting Unit Belts; Checking The Blades; Removing The Bioclip Plug; Adjustment Of Pto Belts - Husqvarna P520 D Operator's Manual

P520 d riding mower
Hide thumbs Also See for P520 D:
Table of Contents

Advertisement

Replacing the cutting unit belts

WARNING! Protect your hands with gloves
!
There is a risk of crush injuries when
working with the belt.
On these cutting units with collision-proof blades, the blades
are driven by one V-belt. Do as follows to change the V-belt:
1 Remove the cutting unit.
2 Remove the screws holding the belt cover and lift it off.
3 Pull the belt off the pulleys. Use a crowbar as necessary
to de-tension the spring and release the belt tension.
4 Loosen two screws and remove the other three for the
bevel gear. Turn the bevel gear so that the belt can be fed
under the pulley.
5 Check that the belt tensioning equipment is not jammed or
binding and replace the spring.
6 Insert the new belt in place and replace the bevel gear.
The bevel gear is tightened to a torque of 47 Nm.
7 Fit the belt around the pulleys. The belt tightening
schedule is on a decal located on the cutting unit under
the belt cover.
8 Fit covers.
9 Attach the cutting unit to the machine, see Attaching the
cutting unit.
Maintenance

Checking the blades

To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades' attachment screws are tight. Screws
should be torque tightened to 84 Nm.
IMPORTANT INFORMATION Replacing or sharpening the
blades should be conducted by an authorised service
workshop.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the service centre assess
whether the blade can be sharpened or must be replaced.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
1 Put the unit in the service position, see Placing in the
service position.
2 Remove the three screws holding the BioClip plug, and
remove the plug.
3 Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.

Adjustment of PTO belts

1 Tighten screw (4) until the sleeve bottoms against the
frame bracket. Tighten lock nut (3) whilst holding screw (4)
firmly.
– 29
English

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents