Advertisement

5.4 Abnormal Screen:

on I314 pin40, pin42, and pin45 which
should have voltage level at 0.7Vpp
Proceed to "5.8 Checking the resolution change
5. Troubleshooting (continued)
Check R.G.B video signals
output from PC host
to D-Sub R.G.B connector
OK
Check the R.G.B signals
max.
OK
Check all LVDS signal pins
of I314 whether if
output correct signals.
OK
IC movement" section.
Failure Point
NG
1. Check connected PC host if there's no R.G.B
signals output.
2. Video signal cable disconnected.
Failure Point
Green, Blue, Red signals are flow in the same
path. In the case, the Red signal is example.
1. Printed wire is broken between D-Sub [R] and
I314 pin45.
NG
2. R391 is short.
3. C356 is open.
4. R390 is open.
Failure Point
1. The I314 is defected.
NG
2. Printed wire is broken between I314 and P306.
23