Download Print this page

Acer P243W Service Manual page 14

Lcd display
Hide thumbs Also See for P243W:

Advertisement

Connect cable into inverter board(CN001)
S7
Take an inverter shielding bracket to cover the
inverter board
Use a Phillips-head screwdriver screwed the
No.1~6 screws till that inverter shielding bracket
and bracket chassis base firmly attached.
(No1~6 screw size=M3x4; Torque=9~10KGFxCM).
Connect the FFC cable to the connector of the LCD
S8
panel.
Turn the monitor faced down and put it on the
S9
bracket chassis module till both parts firmly
Connect FFC cable to LCD panel. There are
two locks over here when plugging in should be
noticed
4. Assembly and Disassembly Procedures (continued)
1
4
CNOO1
2
5
3
6
Take lamp cables out from the holes shown as the
S10
photo.
Plug 6 lamp cables to the connectors of inverter
S11
board.
ACER P243W
Go to cover page
Plug in parallel direction
Angel < 5 degrees
13

Hide quick links: