Set and unset groups

It is possible to split the alarm system into separate areas or groups that can be set
and unset independently. Users can be assigned:
access to any combination of groups,
the option to set and unset all their groups together, or the option to choose
individual groups to set and unset.

Set and unset without group choice

To set and unset without group choice follow the standard procedures on the
previous pages.

Set and unset with group choice

Setting is initiated as normal using a code, tag or fob. However, a choice of groups
is then displayed along with the current status of each group.
To set and unset with group choice:
1. Initiate setting or unsetting as described earlier in the guide.
2. Select an option for each group. Press the appropriate group number to cycle
through the possible options. An example is shown below:
The options are:
U = Unset
R = Ready
F = Fault (group unset and at least 1 zone is open)
S = (flashing) group selected for setting
S = (steady) group already set
3. Press
to implement the status shown.
ent
If a code, keyfob or tag/card is used while an entry timer is running or an alarm is
in progress, the group that is active is unset immediately, without requiring a status
change on the keypad.