Electrical Connection - Siemens Viva Operating And Installation Instructions

Hide thumbs Also See for Viva:
Table of Contents

Advertisement

Available languages

Available languages

Prior to installation
Circulating-air mode
With activated carbon filter if exhaust-air
mode is not possible.
The complete installation set can be
obtained from specialist outlets.
The corresponding accessory numbers can
be found at the end of these operating
instructions.
Preparing the wall
The wall must be flat and perpendicular.
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Weight in kg:
Exhaust air
60 cm
15,0
90 cm
17,5
We reserve the right to construction changes within the
context of technical development.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
Blue
Brown
If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
24
Recirculating air
17,0
19,5
– Earth
– Neutral
– Live
Electrical connection
This is what you have to do:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
'E' or with the symbol (
coloured green or green and yellow.
2. Connect the blue (Neutral) wire to the
terminal in the plug marked 'N' or
coloured black.
3. Connect the brown (Live) wire to the
terminal marked 'L', or coloured red.
The extractor hood should only be
connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
behind the chimney panelling.
The earthed socket should be
connected via its own circuit.
If the earthed socket is no longer
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified
person in order to prevent serious injury to
the user.
Electrical data:
Are to be found on the name plate inside
the appliance after removal of the filter
frame.
Before undertaking any repairs,
always disconnect the extractor hood from
the electricity supply.
Length of the connecting cable: 1.30 m.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
), or

Advertisement

Table of Contents
loading

Table of Contents