5. Measurement
1.
Measuring ambient light
In this measurement mode, we have the choice of shutter priority mode, aperture priority mode and
EV mode. Hold down the Mode set button !0 and turn the Jog wheel t to select ambient measurement
mode
.
1-1 Shutter Speed Priority mode
Hold down the Mode set button !0 and turn the
1.
Jog wheel to select Shutter Speed Priority mode
.
2.
Turn the Jog wheel to set the desired shutter
speed.
Press the Measuring button ! 4 to make a
3.
measurement. Release the Measuring button to
complete the measurement. The measured value
(aperture value) at that time will be displayed.
While pressing the Measuring button, the meter
measures continuously until it is released.
Reference:
• It is possible to switch between full, 1/2 and 1/3 shutter speeds with custom setting
(see page 32).
• You can set shutter speeds from 30 minutes to 1/8000 seconds. After 1/8000 the shutter
speeds of 1/200 and 1/400 can be set.
• After measurement, the F stop value corresponding to the shutter speed is displayed
when the shutter speed is changed.
• The L-558 displays the measured aperture value in either full or half stop increments on
the analog scale, while L-558 CINE displays it in either full or 1/3 stop increments.
• "E.u" (Exposure under) or "E.o" (Exposure over) appears when the combination of shutter
speed and aperture is outside the display range. Changing the shutter speed or aperture
with the Jog wheel will allow you to find a combination that is possible.
• If the "E.u" or "E.o" readout blinks, this indicates that the light level is beyond the
measurement range of the light meter. Adjust lighting in this case.
-12-
POWER
AVE./ EV
A
ISO 1 b
ISO 2 c
MODE
MEMORY d
Set
shutter speed
Measured f stop
value
Measured f stop
1/10
f stop