8. Technical Data
· Other features
All-weather feature
Memory function
Memory clear • recall function
Multiple Flash function
Average function
Brightness Difference function : +/- 9.9 EV (in 1/10 stop)
Flash analyzing function
Exposure Out of Range
Exposure compensation
Calibration compensation
Battery Power Indicator display: with a symbol in 3 status
Auto Power Off
Auto illumination
· DIP switch mode selection
· Second ISO film speed setting : ISO 3 to 8000 (in 1/3 stop)
· Battery used
· Operating temperature range : -10 ~ 50 C
· Storage temperature range
· Dimensions
· Weight
· Standard accessories supplied : Lumigrid, Soft case, strap, synchro terminal cap, CR123A lithium
· Radio wave frequency
FCC & IC
CE
Features and specifications are subject to change without notice.
-34-
: JIS standard water resistance class 4, splash-proof type
: 9 readings
: Up to
flash readings (Only one digit is displayed when the cumu-
lated number is ten or more.)
: Up to 9 readings can be averaged.
: 0 to 100% in 10% in crements
: Eu (underexposure) or Eo (overexposure) indication
: +/- 9.9 EV (in 1/10 steps)
: +/- 1.0 EV (in 1/10 steps)
: 20 minutes after last use
: EV 6 and under
: one of CR123A battery (lithium dry cell)
: -20 ~ 60 C
: 60 w
155 h
37 d mm
: 153 g (with battery)
battery
1
: CH1 ~ 16
CH17 ~ 32
: CH1 ~ 16
CH17 ~ 32
344.0MHz
346.5 ~ 354.0MHz
433.62MHz
434.22MHz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents