Table 15: Power Unit Status Sensors Typical Characteristics; Table 16: Power Unit Status Sensor - Sensor Specific Offsets - Next Steps - Intel S1400FP Manual

Epsd platform based on intel xeon processor e5 4600/2600/2400/1600/1400 product families
Table of Contents

Advertisement

System Event Log Troubleshooting Guide for EPSD Platforms Based on Intel
Sensor Specific Offset
Hex
Description
00h
Power down
02h
240 VA power down
04h
A/C Lost
Revision 1.1

Table 15: Power Unit Status Sensors Typical Characteristics

Byte
Field
11
Sensor Type
09h = Power Unit
12
Sensor Number
01h
13
Event Direction and
[7] Event direction
Event Type
[6:0] Event Type = 6Fh (Sensor Specific)
[7:6] – 00b = Unspecified Event Data 2
14
Event Data 1
[5:4] – 00b = Unspecified Event Data 3
[3:0] = Sensor Specific offset as described in Table 16
15
Event Data 2
Not used
16
Event Data 3
Not used
Table 16: Power Unit Status Sensor – Sensor Specific Offsets – Next Steps
Description
System is powered down.
240 VA power limit was exceeded and the
hardware forced a power down.
A/C power was removed.
Intel order number G90620-002
Xeon
Processor E5 4600/2600/2400/1600/1400 Product Families
®
®
Description
0b = Assertion Event
1b = Deassertion Event
Informational Event
This could have been caused by many things.
1.
If you recently added hardware, try removing it.
2.
Remove/replace any add-in adapters.
3.
Remove/replace the power supply.
4.
Remove/replace the processors, DIMM, and/or hard drives.
5.
Remove/replace the boards in the system.
Informational Event
Power Subsystems
Next Steps
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents