11.4. Checking and Repairing of
Jupiter P.C.B.
11.4.1. Checking and Repairing side B of
Jupiter P.C.B.
Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Attach 30P FFC to the connector (CN2000) on Main
P.C.B..
Step 4 Attach 30P FFC to the connector (CN2003) on Main
P.C.B..
Step 5 Side B of Jupiter P.C.B. can be checked and repaired as
diagram shown.
11.4.2. Checking and Repairing side A of
Jupiter P.C.B.
Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Remove the Jupiter P.C.B.
Step 4 Position Front Panel Unit as shown.
Step 5 Attach 30P FFC to the connector (CN2000) on Main
P.C.B.
Step 6 Attach 30P FFC to the connector (CN2003) on Main
P.C.B..
Step 7 Position Jupiter P.C.B. on the insulated material.
Step 8 Side A of Jupiter P.C.B. can be checked & repaired as
diagram shown.