Harman Stove Company P61-2 Owner's Manual page 11

Harman stove owners manual pellet stove p61-2
Table of Contents

Advertisement

3" min.
3" min.
PL  vent  manufacturer's
firestop spacer and support
#8 Installing through the ceiling vent
Through  the  ceiling  vent,  follow  PLvent
manufacturers  recommendations  when  using  wall
and ceiling pass through.
Storm collar
Flashing
3" min.
No  insulation  or
other  combustible
materials 
allowed  within  3"
of the PL vent pipe.
(See  Page  9  for
c o r n e r
i n s t a l l a t i o n
clearances)
Fig. 14
Fig. 16
Venting
Minimum  flue  vent
configuration
are
It is recommended that
outside air be installed with this
venting configuration.
DO  NOT  INSTALL  A  FLUE  DAMPER  IN  THE
EXHAUST  VENTING  SYSTEM  OF  THIS  UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
INSTALL  VENT  AT  CLEARANCES  SPECIFIED
BY  THE  MANUFACTURER
DO  NOT  INSTALL  IN  SLEEPING  ROOM
THE  STRUCTURAL  INTEGRITY  OF  THE
MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF  MUST  BE  MAINTAINED.
THE STOVE IS HOT WHILE IN OPERATION.
KEEP  CHILDREN,  CLOTHING  AND
FURNITURE AWAY.  CONTACT MAY CAUSE
SKIN  BURNS.
 11
Fig. 15
WARNING
CAUTION
CAUTION