Staple cartridge replacement and staple jam removal

When the staple cartridge becomes empty or staples become jammed, a message will appear in the message
display of the operation panel.
Follow the procedure below to replace the staple cartridge or remove jammed staples.
I I I I Staple cartridge replacement
Open the front cover.
1
2
Pull out the stapler section.
3
Turn roller rotating knob A in the direction of
the arrow to move the staple unit to the front.
Roller rotating
knob A
Staple unit
4
Remove the empty staple box.
5
Remove the empty staple cartridge.
NOTE
If staples remain, the staple cartridge cannot
be removed.
Turn the roller rotating
knob until the triangle
mark is aligned with the
index.
Press the lock button to
unlock the staple box
cover and remove the
staple cartridge.
SADDLE STITCH FINISHER
Insert a new staple cartridge into the
6
staple box.
NOTES
G Do not remove the tape from the cartridge before
inserting the staple cartridge into the box.
G Make sure that the new staple cartridge is locked
securely in the staple box. Press down on the
staple box cover until you hear a "click" indicating
that the staple cartridge is locked.
Remove the tape from the staple cartridge
7
by pulling it straight.
Insert the staple box.
8
Push the stapler section back into the
9
finisher.
10
Close the front cover.
NOTE
Make a test print or copy in the staple sort mode to
ensure that stapling is performed properly.
After inserting the staple
cartridge, press down on
the staple box cover to
lock the cartridge in
place.
Push the staple box in
until it clicks into place.