Troubleshooting - Central Pneumatic 67697 Set Up And Operating Instructions Manual

145 psi 3 hp twin cylinder air compressor pump
Table of Contents

Advertisement

Problem
Compressor builds
1.
pressure too slowly
2.
3.
Compressor not
1.
building enough air
2.
pressure
3.
High Oil
1.
Consumption
2.
3.
Overheating
1.
2.
3.
4.
Excessive noise
1.
2.
3.
4.
5.
Oil in discharge air
1.
2.
Air leaks from pump
Loose fittings.
or fittings
Follow all safety precautions whenever diagnosing or servicing the
compressor. disconnect power supply before service.
SKU 67697

Troubleshooting

Possible Causes
Crankcase overfilled with oil or
oil too thick.
Working environment too cold.
Loose fittings.
Filter need cleaning/replacing.
Crankcase oil too thick.
Loose fittings.
Crankcase oil too thin.
Unit not on level surface.
Crankcase vent clogged.
Filter need cleaning/replacing.
Crankcase oil incorrect type
and/or thickness.
Crankcase oil level too low.
Unusually dusty environment.
Crankcase overfilled with oil
or oil is incorrect thickness or
type.
Crankcase oil level too low.
Loose or damaged belt guard.
Loose fittings.
Unit not on level surface.
Crankcase oil too thin or
crankcase overfilled with oil.
Crankcase vent clogged.
For technical questions, please call 1-800-444-3353.
likely Solutions
1.
Drain oil and refill to proper level with recommended oil.
2.
Move unit to a warmer location. Check that recommended oil
is in crankcase.
3.
Reduce air pressure, then check all fittings with a soap solution
for air leaks and tighten as needed. Do not overtighten.
1.
Check inlet and outlet filter. Clean and/or replace as needed.
2.
Drain oil and refill to proper level with recommended oil.
3.
Reduce air pressure, then check all fittings with a soap solution
for air leaks and tighten as needed. Do not overtighten.
1.
Drain oil and refill to proper level with recommended oil.
2.
Reposition unit on a level surface.
3.
Clean Crankcase vent.
1.
Check inlet and outlet filter. Clean and/or replace as needed.
2.
Drain oil and refill to proper level with recommended oil.
3.
Add oil to proper level, check for leaks.
4.
Clean and/or replace filter more often or move unit to cleaner
environment.
1.
Drain oil and refill to proper level with recommended oil.
2.
Add oil to proper level, check for leaks.
3.
Replace belt guard.
4.
Reduce air pressure, then check all fittings with a soap solution
for air leaks and tighten as needed. Do not overtighten.
5.
Reposition unit on a level surface.
1.
Drain oil and refill to proper level with recommended oil.
2.
Clean Crankcase vent.
Reduce air pressure, then check all fittings with a soap solution for
air leaks and tighten as needed. Do not overtighten.
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents