Fitting The Stability Bracket - Tricity Bendix SIM 533 Operating And Installation Instructions

Cooker
Table of Contents

Advertisement

INSTALLATION INSTRUCTION

FITTING THE STABILITY BRACKET

It is recommended that if the appliance is to be installed with a flexible supply pipe and a stability bracket
(SK.4729.A) is fitted and is available from your supplier (see Important Safety Requirements, Page 32 ). These
instructions should be read in conjunction with the leaflet packed with the stability bracket.
1. Place the appliance in its intended position and level appliance.
2. Mark off 300 mm from the left hand side of the appliance as shown in dimension 'A' Fig 4a. This is the centre line
of the fixing bracket.
3. Draw a line 100mm from the front edge of the levelling feet (see Fig.4a) and remove appliance from its position.
Mark off dimension B (see Fig.4a) back from this line on the centre line of the bracket to locate the front edge of
the lower bracket. Fix lower bracket (with two fixing holes) to the floor then measure the height from floor level to
engagement edge on back of appliance, dimension 'C' of Fig.4b.
4. Assemble upper bracket to lower bracket so that underside of bracket is dimension 'C' + 3mm above floor level.
Reposition appliance and check that top bracket engages into appliance back as shown in Fig. 4b.
(A)
300mm
Fig 4a
100mm
(
)
C
Fig 4b
36

Advertisement

Table of Contents
loading

Table of Contents