Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop Parity None
8 Data, 1 Stop, Parity Even
8 Data, 1 Stop, Parity Odd

RS-232 Receiver Time-Out

The unit stays awake to receive data until the RS-232 Receiver Time-Out
expires. A manual or serial trigger resets the time-out. When an RS-232
receiver is sleeping, a character may be sent to wake up the receiver and reset
the time-out. A transaction on the CTS line will also wake up the receiver. The
receiver takes 300 milliseconds to completely come up. Change the RS-232
7 Data, 1 Stop, Parity None
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop, Parity Odd
* 8 Data, 1 Stop, Parity None
2 - 11