Locatinq The Anti-Tip Bracket (See Fiqure 4)
Installations With Alternate Outlet Receptacle (Non-Flush Mount)
If the outlet receptacle must be mounted as shown in figure
4, the range will not push back against the wall.
Therefore, the long leg of anti-tip bracket will have to be on
the floor to properly engage the leveling foot.
A.
Determine where either the right or left "EDGE" of the
range will be located and mark the floor or wall.
B.
Place the bracket 15/16" (24 mm) from the marked
"EDGE" toward the center of opening and against the
back wall as shown in figure 4, with orientation hole
against floor.
C. Use the bracket as a template and mark the required
holes as shown in figure 4 for the type of construction
you will be using.
NON-FLUSH
MOUNT
OUTLET RECEPTACLE
(SEE
FIGURE
2 FOR
LOCATION
SEE FIGURES 7 & 8 FOR
--_
.t..
ROTATION
OF OUTLET
"_
./
_
/*
HOLE
FOR
WALL
I
I
I
I/
[24-
mini
FR Olvl EDGE
OF
RANGE
MARKED EDGE
OF RANGE
-ATTACH
ANTI-TIP
BRACKET
WITH
LONG
SCREWS
ION
HOLE
I-TIP
BRACKET
__
_--LEVELING
"_
_FOOT
HOLES
FOF_
FLOOR
FIGURE 4
STEP 2 - Anti-Tip
Bracket Installation Options
A. Wood Construction:
1.
Floor: Locate the center of the two holes identified in
figures 3 and 4 as applicable, as "HOLES FOR
FLOOR." Drill a 1/8" (3 mm) pilot hole in the center
of each hole (a nail orawl may be used ifa drill is not
available). Secure the ANTI-TtP bracket to the floor
with the two screws provided. Proceed to STEP 3.
.
Wall: Locate the center of the two holes identified in
figures 3 and 4 as applicable, as "HOLES FOR
WALL." Drill an angled 1/8" (3 mm) pilot hole in the
center of each hole as shown in figure 5. (A nail or
awl may be used ifa drill is not available). Secure the
ANTI-TIP
bracket to the wall with the two screws
provided as shown in figure 5. Proceed to STEP 3.
B.
Cement or Concrete
Construction:
1.
Suitable screws for concrete construction
can be
obtained at the hardware store. Drill the required
size hole for
the hardware
obtained
into the
concrete at the center of the holes identified in
figures 3 and 4 as applicable, as "HOLES FOR
FLOOR". Secure the ANTI-TIP bracket to the floor.
Proceed to STEP 3.
NOTE:
USE A MINIMUM
OF (2)
SCREWS TO
INSTALL
ANTI-TbP
BRACKET
(SEE
FbGURES
3 AND
4 FOR
PROPER
ORbENTATION)
TO THE WALL
OR
FLOOR.
SCRL_!S
MUST -
ENTER
WOOD
OR METAL.
WALL
-ANTI-TIP
BRACKET
-SCREW
BRACKET
SLIDE
IN
TO SECURE
ARTJ 9215-104