Before Operating; Do Not Use An Extension Cord - Maytag MDE2400AZW Installation Instructions Manual

Automatic dryer
Table of Contents

Advertisement

If a power cord is not used and the electric dryer is to be permanently wired, the dryer must
be connected to a grounded metal, permanent wiring system; or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding
terminal.
ELECTRICAL
CONNECTIONS
BEFORE
OPERATING
OR TESTING,
follow all grounding
instructions
in Grounding
Section.
An individual
branch (or separate)
circuit serving only this appliance
is
recommended.
DO NOT USE AN EXTENSION CORD.
ELECTRIC
MODELS - U.S. Only
Most U.S. dryers, as manufactured,
require a 120/240 volt, 60 Hz AC approved
electrical
service.
Some require 120/208 volt, 60 Hz approved
electrical
service. The electric service
requirements
can be found on the data label located on the front behind the door. A 30-
ampere fuse or circuit breaker on both sides of the line is required.
_WARNING
• improper connection of the equipment grounding conductor can result in a risk of electric
shock, Check with a qualified electrician or serviceman if you are in doubt as to whether
the appliance is properly grounded, Do not modify the plug provided with the appliance - if
it will not fit the outlet, have a proper outlet installed by a qualified electrician,
To prevent unnecessary risk of fire, electrical shock or personal injury, aii wiring
and grounding must be done in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA No, 70-Latest Revision (for the US)
or the Canadian Electrical Code CSA C22,1 - Latest Revisions and local codes and ordinances, it is the
personal responsibility and obligation of the appliance owner to provide adequate electrical services for
o All gas installations must be done in accordance with the national Fuel Code ANSI/Z2231 =Last revision
(for United States) or CAN/CGA = B149 Installation Codes = Latest Revision (for Canada) and local codes
and ordinances,
A 120/240-volt
U.S. electric
dryer must be converted
if it is to operate
on a 120/208 volt
electrical
system.
If a power cord is used, the cord should be plugged into a 30-ampere
receptacle.
The power cord is NOT provided
with U.S. electric
model dryers.
IMPORTANT:
When permitted
by local codes, the dryer electrical
supply may be connected
by
means of a new power supply cord kit, marked for use with clothes dryer, that is U.L. listed, rated at
120/240 volts minimum,
30 amperes
with three No. 10 copper wire conductors
terminated
with closed
loop terminals,
open-end
spade lugs with turned up ends or with tinned leads.
Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring
must be retained at the dryer cabinet with a suitable
UL listed strain relief.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mde2400ayw

Table of Contents