The static pressure in any exhaust system must not exceed 0.48 inches of
water column, or be less than 0.
This can be measured
with the dryer running with a manometer
at the point where the
exhaust duct connects
to the dryer. A no heat setting should be used. The dryer tumbler
should be empty and the lint filter clean.
NONEXHAUSTED
INSTALLATIONS
°
If the electric dryer is not exhausted
to the outside, the exhaust must not terminate
directly behind the dryer.
°
Use a rectangular
vent kit along with a Dacron mesh lint bag (see Accessories).
Maintain
a 6" (15.2 cm) clearance
between the back of the control panel and the wall.
Although
the lint screen and lint bag will retain most of the lint, a certain amount will be
expelled
into the laundry area.
°
WARNING:
IF THE DRYER IS NOT EXHAUSTED
TO THE OUTSIDE,
SOME FINE
LINT WILL BE EXPELLED
INTO THE LAUNDRY
AREA.
AN ACCUMULATION
OF
DUST OR LINT IN ANY AREA OF THE HOME CREATES
A FIRE HAZARD.
ANY
LINT ACCUMULATIONS
MUST BE CLEANED
FREQUENTLY.
ELECTRICAL
REQUIREMENTS
NOTE: Wiring diagram
is located inside the lower kick panel.
Export models
(not U.S. or Canada):
See Additional
Instructions for Export Models on
last page of installation instructions.
_-WARNING
WARNING
- To prevent unnecessary
risk of fire, eUectricaU shock
or personal
injury, all
wiring
and grounding
must
be done
in accordance
with
iocam codes,
or in the
_
bsence
of locam codes,
with
the Nationam Electricam
Code,
ANSm!NFPA
(for the
United
States)
or the Canadian
Electrical
Code
CSA C22.1 (for Canada).
GROUNDING
This dryer must be grounded.
In the event of malfunction
or breakdown,
the ground will
reduce the risk of electrical
shock by providing
a path of least resistance
for electrical
current.
NEVER
CONNECT
GROUND
WIRE TO PLASTIC
PLUMBING
LINES, GAS LINES OR HOT
WATER
PIPES.
ELECTRIC
MODELS
U.S. electric models are shipped with a ground strap connected
from the neutral terminal
block post to the frame of the dryer. If local codes prohibit the use of the ground strap, the
dryer must be grounded
in accordance
with local codes.