Maytag MEDX5SPAW0 Installation Instructions Manual page 12

27" wide models
Hide thumbs Also See for MEDX5SPAW0:
Table of Contents

Advertisement

Available languages

Available languages

_3,
Connect
neutral
wire
Place hooked end of neutral wire (white or
center) (C) of direct wire cable under center
terminal block screw (B). Squeeze hooked
end together. Tighten screw.
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
f3,
Connect
remaining
wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down
screw. Now, go to
"Venting Requirements."
Optionam 3oWire Connection
IMPORTANT:
You must verify with a qualified
electrician that this grounding method is acceptable
before connecting.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
12
Connect a separate copper ground wire (G) from the external
ground conductor
screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down
screw. Now, go to
"Venting Requirements."