• Only a 4-conductor power-supply cord kit
rated 120/240 volts, 50 amperes and
marked for use with ranges with closed-
Io0p connectors or open-end spade lugs
with upturned ends shall be used. The
middle (neutral) wire of the power cord or
4-wire conduit has to be connected to the
middle post of the main terminal block. The
other two wires of the power cord or
conduit have to be connected to the
outside posts of the main terminal
connection block. The 4th ground wire
must be connected to the frame of the
range with the ground screw.
- Failure to do so can result in electrical shock, severe
personal injury or death.
Follow the instructions
under " [4]CONNECT
RANGE
CORD" on page 5 to correctly install the strain relief.
1. Remove the lower 3 screws from the terminal
block
and retain them. (Refer to Figure 9.)
Remove the ground
screw and retain it.
2. Remove ground strap and discard as shown
in Figure 9.
Do not discard any screws.
3. Insert the ground screw into the power cord ground
wire terminal
ring and secure it to the range frame.
4. Insert the 3 screws through
each power cord
terminal
ring and into the lower terminals
of the
terminal
block. Make sure that the center wire
(white/neutral)
is connected
to the center lower
position
of the terminal
block.
Tighten 3 screws securely into the terminal
block.
5. Go to page 9.
4-wire connection
Black
White
Red
block
strap
_
strap
and discard
7"
\c
Ground screw_Conduit
''connection
plate
FIGURE 9
Install the conduit as follows:
Remove the Conduit connection
plate from the rear of
drawer body and rotate it as shown in Figure 5. The
conduit
hole (1%") must be used.
First, prepare conduit wires as shown in Figure 10.
3 wire
4 wire
Conduit
connection
plate
I"
3/8"
(2.5cm)
(0.9 cm)
or
31/2"
(8.9 cm)
1"
3/8"
(2.5cm)
(0.9 cm)
Ground
\
( 1._/€;'m) w, re
t6.9cm)
FIGURE 10
Second, install conduit as shown in Figure 6.
For conduit
installations,
after purchasing
a strain
relief, insert it in the conduit
hole (11/8"). Then install
the conduit through
the body of strain relief and
fasten the strain relief with its ring. Reinstall the
bracket.
For conduit connections
:
If the wire in the conduit
is copper it must be 8 or 10
AWG wiring.
If the wire in the conduit
is aluminum
it must be 6 or 8
AWG wiring.
1. Loosen the lower 3 screws from the terminal
block.
(Refer to Figure 11.)
2. Insert the bare wire (white/neutral)
end through
the
center terminal block opening.
Do not remove ground strap connections.
3. Insert the two side bare wire ends into the lower left
and the lower right terminal
block opening.
Tighten the 3 screws securely into the terminal block.
(approximately
35 - 50 IN-LB)
4. Go to page 9.