11. Check the voltage at the terminals in the inspection point in the power control unit.
Caution:
Wear insulated gloves.
To prevent serious injury or death, do not proceed with dismantling of the HV
system until the voltage at the terminals in the inspection point is 0 V.
Standard voltage: 0 V
Hint:
Set the tester to DC 750 Volts measure the voltage.
This inspection is performed to verify that it is safe to remove the HV battery.
For LHD
For RHD
Inspection Point
Inspection Point
21