4.
Attaching the Island Trim
36" (91.4} model shown
5=
Using the final measurement from Step 3, measure from the
floor up and mark a horizontal line on the wall where a wall
stud is located.
i
j
I
D
I
I
'
,
I
I
I
I
I
I
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D. Anti-tip bracket
Position top of anti-tip bracket at line marked in Step 4 and
mark holes. Drill two 1/8"holes at the positions marked on the
wall. Use screws provided to fasten anti-tip bracket to wall.
Anti-tip bracket must be mounted securely to stud in wall
behind the range. Depending on thickness of the wall, longer
screws may be required. Longer screws are available from
your local hardware store.
Excessive
Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move range close to cabinet
opening.
2. Remove cardboard or hardboard from under range. Move
range into final position.
3. Attach the backguard or island trim as required for your
installation. See "Tools and Parts." Attachment
screws are
included in the literature package.
Attaching the Backguard
36" (91.4 cm) model shown
A. 3 front screws (4 rear screws required but not shown)
A. Center hole not used
4=
Using 2 or more people, tip the range back so that the front
feet lift off the ground. Slide range toward the wall until the
rear brace is under the anti-tip bracket. Stand range up,
making sure the anti-tip bracket catches the rear brace.
1. Assemble flexible connector from gas supply pipe to pressure
regulator located in the middle front of the range.
2, Apply pipe-joint
compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in following illustration).
3. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
4. Use a Wld' combination
wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
B
C
D
_
E
H
G
A. Gas pressure regulator
B. Use pipe-joint
compound
C. Adapter (must have Y2"male
pipe thread)
D. Flexible connector
F
E Manual gas shutoff valve
F Y," or 3/4"gas pipe
G. Use pipe-joint
compound
H. Adapter
Complete
Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2=
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.