Pre-lnstallation
Requirements
.................................................
2
Electrical
Requirement
..........................................
2
Grounding
Requirement
........................................
2
Water
Supply
Requirements
..........................................
2
Drain
Requirements
................................................
2
Location
Of Your
Washer ...........................................
2
Unpacking
......................................................
2-3
Rough-In
Dimensions
.............................................
3
Installation
.......................................................
4
Replacement
Parts ...............................................
4
PRE-INSTALLATION
REQUIREMENTS
Tools Required for installation:
1.
1/4 in. nut driver
2.
3/8 in. socket with ratchet.
3.
3/8 in. open end wrench.
4.
7/16 in. socket with ratchet.
5.
9/16 in. open end wrench.
6.
Channel-lock adjustable pliers.
7.
Carpenter's level.
ELECTRICAL
REQUIREMENTS
CIRCUIT-
Individual,
properly polarized and grounded
15 amp.
branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60
Hz, Alternating
Current. NOTE: The use of this washer with power
created by gas powered generators, solar powered generators, wind
powered generators or any other generator
other than the local
utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to
be located so the power supply cord is accessible when the washer is
in an installed
position.
NOTE: GFI (Ground
Fault Interrupter)
receptacle is not required.
GROUNDING
REQUIREMENTS
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a licensed
electrician if you are in doubt as to whether the appliance is properly
grounded.
1.
The washer MUSTbe
grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electrical shock by
a path of least resistance for electrical current.
2.
Since your washer is equipped with a power supply cord having
an equipment-grounding
conductor and a grounding plug, the
plug MUST be plugged
into an appropriate,
copper wired
receptacle that is properly installed and grounded in accordance
with all local codes and ordinances or in the absence of local
codes, with the National Electrical Codes, ANSI/NFPA 70 (latest
edition). If in doubt, call a licensed electrician. DO NOTcut
off
or alter the grounding
prong on the power supply cord. In
situations where a two-slot receptacle is present, it is the owner's
responsibility
to have a licensed electrician
replace it with a
properly
grounded
three prong grounding
type receptacle.
WATER
SUPPLY
REQUIREMENTS
Hot and cold water faucets MUSTbe installed within 42 inches (107
cm) of your washer's water inlet. The faucets MUSTbe
3/4 inch (1.9
cm) garden hose type so inlet hoses can be connected. Water pressure
MUST be between 10 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water department can
advise you of your water pressure.
DRAIN
REQUIREMENTS
1.
Drain capable of eliminating
17 gals (64.3 L) per minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3.
The standpipe height above the floor should be:
Minimum
height:
24 in. (61 cm)
Maximum height:
96 in. (244 cm)
96 m.
(244 cm)
NOTE:
24 in.
(61 cm)
Min.
Drain hose attached to the washer can reach a 58 in. (147 cm)
high standpipe. For higher standpipe use hose P/N 131461201,
available from an authorized
parts distributor.
If drain is less
than 24 in. (61 cm), install a siphon break kit, available at your
local hardware store.
LOCATION
OF YOUR WASHER
DO NOT INSTALL YOUR WASHER:
1.
In an area exposed to dripping
water
or outside
weather
conditions.
The ambient temperature
should never be below 60
degrees F (15.6 degrees C) for proper washer operation.
2. In an area where it will come in contact with curtains or drapes.
3. In an area (garage or garage-type building) where gasoline of
other flammables are kept or stored (including automobiles).
4. On carpet. Floor MUST be solid with a maximum slope of 1/2 in.
per foot (1.27 cm per 30.5 cm). To ensure vibration or movement
does not occur, reinforcement of the floor may be necessary.
IMPORTANT
MINIMUM
INSTALLATION CLEARANCES
When installed
in alcove or doset:
Sides, Rear = 0 in. (0 cm)
Top = 0 in. (0 cm) Front Console Model
Top = 15 in. (38.1 cm) Rear Console Model
When installedin
closet: Front= l in. (2.54 cm)
Closet door ventilation required:
2 Iouvered openings each 60 in2(387 cm2), 3 in. (7.6 cm) from top
and bottom of door.
UNPACKING
1
Cut the shipping carton along the dotted line along the base of
the unit.
2 While in the carton carefully lay the washer on its back side.
3
Remove the styrofoam base.
4. Carefully return the washer to an upright position and remove
the carton.

Advertisement